Rmon alarm and event defaults, B-18, Rmon alarm and event – Paradyne CSU User Manual
Page 366: Defaults, In appendix b, Snmp mibs and traps, and rmon alarm defaults, t
B. SNMP MIBs and Traps, and RMON Alarm Defaults
B-18
September
2002
9128-A2-GB20-80
RMON Alarm and Event Defaults
The FrameSaver unit supports automatic generation of RMON alarm and event
information. Each alarm sets an SNMP variable to monitor. When the threshold set
for the monitored variable is exceeded, an SNMP trap or a log event is sent.
Event Defaults
Since all events sent are under the control of the FrameSaver unit, there is no
need to define multiple events for each alarm type, so only the following two events
need to be generated:
The alarm default tables starting on the next page show how each RMON default
alarm is set by the FrameSaver unit, shows the alarm and event types, the interval
used when generating alarms, and thresholds.
T
Physical Interface Alarm Defaults
T
Frame Relay Link Alarm Defaults
T
DLCI Alarm Defaults – Paradyne Area
T
DLCI Alarm Defaults – NetScout Area
See
Standards Compliance for SNMP Traps
on page B-8 for information about
on page B-16 for traps specific to
remote monitoring.
Dial Control Extension MIB
dialCtlPeerCall-
Rejected
T
callHistoryPeerId
(RFC 2128)
T
callHistoryPeerIfIndex
(RFC 2128)
T
callHistoryLogicalIfIndex
(RFC 2128)
T
callHistoryPeerAddress
(RFC 2128)
T
devLastTrapString
(devHealthAndStatus.-
mib)
A peer-to-peer call was not
successful; the call was rejected
by the far end.
T
ISDN Call Profile has been
disabled.
T
This unit’s phone number was
not in the far end device’s ISDN
Call Profile.
String:
‘Call on $ifString using B-Chnl
$channel rejected by remote.’
Table B-9.
dialControl Traps (2 of 2)
Trap
Variable-Bindings
Possible Cause
eventIndex
eventDescription
eventType
eventCommunity
65533
Default SLV Rising Event
log-and-trap(4)
0
65534
Default SLV Falling Event
log-and-trap(4)
0