Dbm interface status – Paradyne CSU User Manual
Page 220
7. Operation and Maintenance
7-38
September
2002
9128-A2-GB20-80
The following information is available for DSX-1 interface time slots (D01– D24):
DBM Interface Status
When an ISDN DBM is installed, these interface statuses appear when DBM
Interface Status is selected from the Status menu.
Main Menu
→
Status
→
DBM Interface Status
DBM Interface Status Screen Example
Select the NextLink and PrevLink function keys to move forward or backward
through the frame relay link that can be selected. If the selected frame relay link is
a multilink aggregate link, select the ConstLinkStatus function key to see the
status for selected constituent links.
For a multilink aggregate link, Multilink Constituent Link appears under Link so a
specific constituent link can be selected. Otherwise, the line is blank. In addition,
the Most Recent Cause Value, Previous Cause Values, and Remote Call ID do not
appear for a multilink aggregate frame relay link.
The Cross Connect
Status Field (bottom) . . . Indicates the . . .
blank
The time slot is unassigned.
Net1
/tt
Network interface 1, time slot
(tt)
is assigned to DSX-1 time
slot (01 to 24) using Clear Channel.
Net1
/tt
r
Network interface 1, time slot
(tt)
is assigned to DSX-1 time
slot (01 to 24) using Robbed Bit Signaling ( r ).
main/status/dbm 9128-II
Device Name: Node A 5/26/2000 23:32
DBM INTERFACE STATUS
Line Status: Call Rejected - HQ_Site: Disabled
Link: Colorado
Multilink Constituent Link: Colorado-1
Link Operating Mode: Active
Call Status: Connected
Most Recent Cause Value: Call Awarded and Being Delivered In Est Chnl-7
Previous Cause Value 1: None
2: None
3: None
4: None
Maximum Link Rate (Kbps): 64K (Configured)
Negotiated Rate (Kbps): 64K
ISDN Channel: B1
Remote Call ID: 8135302000
--------------------------------------------------------------------------------
Ctrl-a to access these functions, ESC for previous menu MainMenu Exit
Refresh
NextLink PrevLink
ConstLinkStatus