Service level verification performance statistics – Paradyne CSU User Manual
Page 234
7. Operation and Maintenance
7-52
September
2002
9128-A2-GB20-80
Service Level Verification Performance Statistics
These statistics appear when Service Level Verification (SLV) is selected from the
Performance Statistics menu.
Main Menu
→
Status
→
Performance Statistics
→
Service Level Verification
They only appear for the network interface and only if DLCIs are multiplexed or IP
Enabled.
Information displayed on the SLV Performance Statistics screen depends on DLCI
type. See
Table 7-16, SLV Performance Statistics for Multiplexed DLCI
or
Table 7-17, SLV Performance Statistics for IP Enabled DLCI
.
On either screen, select PrevDLCI or NextDLCI to view statistics for the previous
or next DLCI on the link. On the IP Enabled DLCI screen, select PrevPath or
NextPath to view statistics for the previous or next path associated with the DLCI.
For standard or multiplexed DLCIs, the statistics collected by the unit depend upon
the device at the far end of the connection. If the far-end device is a FrameSaver
SLV unit, frame relay, latency, and FDR/DDR performance statistics are collected.
The Frame Relay Delivery Ratio is the number of delivered frames/offered frames;
the Data Delivery Ratio is the number of delivered octets/offered octets.
If the far-end device is a non-FrameSaver device, or a FrameSaver 9120 or 9620,
only frame relay statistics are collected.
Table 7-16. SLV Performance Statistics for Multiplexed DLCI (1 of 3)
Statistic
What It Indicates
Far End Circuit
Number of the multiplexed DLCI or VPI/VCI (Virtual Path
Identifier/Virtual Channel Identifier) at the other end of the
connection.
If the far-end circuit is a DLCI, the DLCI number (16– 1007)
appears. If a VPI/VCI, the number is displayed as
xx,yyy,
xx
being the VPI number (0 – 15) and
yyy
being the VCI number
(32 – 2047).
None
appears if the unit has not communicated with the other
end.
Far End IP Addr
IP Address of the device at the other end of the multiplexed
DLCI connection.
None
appears if the FrameSaver unit has not communicated
with the other end, or if the device at the other end of the
multiplexed DLCI does not have an IP Address configured.
Dropped SLV
Responses
The number of SLV inband sample messages sent for which a
response from the far-end device has not been received.
* Only appears for FrameSaver units when the SLV Delivery Ratio option is
enabled.