beautypg.com

Service level verification performance statistics – Paradyne CSU User Manual

Page 234

background image

7. Operation and Maintenance

7-52

September

2002

9128-A2-GB20-80

Service Level Verification Performance Statistics

These statistics appear when Service Level Verification (SLV) is selected from the
Performance Statistics menu.

Main Menu

Status

Performance Statistics

Service Level Verification

They only appear for the network interface and only if DLCIs are multiplexed or IP
Enabled.

Information displayed on the SLV Performance Statistics screen depends on DLCI
type. See

Table 7-16, SLV Performance Statistics for Multiplexed DLCI

or

Table 7-17, SLV Performance Statistics for IP Enabled DLCI

.

On either screen, select PrevDLCI or NextDLCI to view statistics for the previous
or next DLCI on the link. On the IP Enabled DLCI screen, select PrevPath or
NextPath to view statistics for the previous or next path associated with the DLCI.

For standard or multiplexed DLCIs, the statistics collected by the unit depend upon
the device at the far end of the connection. If the far-end device is a FrameSaver
SLV unit, frame relay, latency, and FDR/DDR performance statistics are collected.
The Frame Relay Delivery Ratio is the number of delivered frames/offered frames;
the Data Delivery Ratio is the number of delivered octets/offered octets.

If the far-end device is a non-FrameSaver device, or a FrameSaver 9120 or 9620,
only frame relay statistics are collected.

Table 7-16. SLV Performance Statistics for Multiplexed DLCI (1 of 3)

Statistic

What It Indicates

Far End Circuit

Number of the multiplexed DLCI or VPI/VCI (Virtual Path
Identifier/Virtual Channel Identifier) at the other end of the
connection.

If the far-end circuit is a DLCI, the DLCI number (16– 1007)
appears. If a VPI/VCI, the number is displayed as

xx,yyy,

xx

being the VPI number (0 – 15) and

yyy

being the VCI number

(32 – 2047).

None

appears if the unit has not communicated with the other

end.

Far End IP Addr

IP Address of the device at the other end of the multiplexed
DLCI connection.

None

appears if the FrameSaver unit has not communicated

with the other end, or if the device at the other end of the
multiplexed DLCI does not have an IP Address configured.

Dropped SLV
Responses

The number of SLV inband sample messages sent for which a
response from the far-end device has not been received.

* Only appears for FrameSaver units when the SLV Delivery Ratio option is

enabled.

This manual is related to the following products: