4. Configuration Options

4-68

September

2002

9128-A2-GB20-80

Configuring PVC Connections

The Auto-Configuration feature automatically configures PVC Connections and
their DLCI Records. PVC Connections can also be created manually (see

Table 4-15, PVC Connection Options

).

Main Menu

Configuration

PVC Connections

From this screen, you can go directly to the Management PVC screen by selecting
the MgmtPVCs function key for easy movement between screens.

Quick removal of unused DLCIs (and ISDN Link Profiles, except for HQ_Site, if the
model has an ISDN DBM installed) included in an existing PVC Connection is also
available when the Del ete function key is selected and you respond Yes to the

Remove otherwise unused components associated with the
deleted PVC?

prompt.

Table 4-15. PVC Connection Options (1 of 4)

Source Link

Possible Settings: Port-

n

,

ISDN Link Name

, Net1-FR1, Rtr-S0

Default Setting: Initially blank; no default.

Specifies the frame relay interface that starts a PVC connection; the from end of a from-to
link. The only valid settings for this configuration option are frame relay interfaces that
have at least one DLCI or EDLCI defined that are not part of a PVC connection or
management link. For example, if Port-1 has no DLCIs defined, Port-1 would not appear
as a valid setting.

Net1-FR1 – Specifies that the network interface be used in the connection.

ISDN Link Name

– For units with ISDN backup capability, specifies the ISDN link of the

DBM as the source link. This can be any nonnull link name configured on an ISDN frame
relay link.

Port-

n

– For CSU/DSUs, specifies that the frame relay link on the user data port be used

in the connection.

Rtr-S0 – For the FrameSaver SLV 9126-II Router, specifies that the frame relay link on the
virtual router port be used in the connection.

Clear All – Clears all Link and DLCI settings, and suppresses EDLCIs.

Source DLCI

Possible Settings: 16 – 1007
Default Setting: Initially blank; no default.

Specifies the source DLCI for a frame relay interface. The DLCI must be defined and
cannot be part of a PVC connection or management link. For multiplexed DLCIs, at least
one EDLCI must be unconnected for the DLCI to be a valid selection.

NOTE: Source DLCI has no value if Source Link contains no value.

16 – 1007 – Specifies the DLCI number.