beautypg.com

Network lmi-reported dlcis status – Paradyne CSU User Manual

Page 211

background image

7. Operation and Maintenance

9128-A2-GB20-80

September 2002

7-29

Network LMI-Reported DLCIs Status

Network LMI-reported DLCI statuses are selected from the Status menu.

Main Menu

Status

LMI Reported DLCIs

The LMI Reported DLCIs screen displays the status and CIR (if supported by the
switch) for each DLCI, whether the DLCI is configured or not.

LMI-Reported DLCIs Status Screen Example

An asterisk (*) next to the DLCI indicates that the DLCI has been configured for the
link.

DLCIs without an asterisk have not been configured in the unit. These DLCIs pass
through the unit transparently, without being monitored and with no
demultiplexing/multiplexing of management diagnostics or user data being
performed. Only DLCIs on the Net1-FR1 and Port-1 frame relay links appear on
this screen; nonconfigured DLCIs on other links are discarded.

main/status/lmi_dlcis 9128-II

Device Name: Node A 5/26/2000 23:32

frame relay link LMI REPORTED DLCIs Page 1 of 2

DLCI

STATUS CIR (bps) DLCI

STATUS CIR (bps)

* 300

Active

16000 * 622

Active 32000

* 305

Inactive * 624

Active 32000

* 400

Deleted * 625

Deleted

* 410

Inactive * 713 Active 32000

411

Inactive * 822

Active 32000

420

Inactive

32000 * 1002 Active 32000

430

Active

501

Inactive

511 Active 256000

520 Active 64000

* – DLCI is configured on the Frame Relay Link.

--------------------------------------------------------------------------------

ESC for previous menu MainMenu Exit

Refresh PgUp PgDn NextLink PrevLink

This manual is related to the following products: