beautypg.com

Siemens ERTEC200 User Manual

Page 29

background image

FIQIRR

R

Addr.: 0x5000_0050

Default: 0x0000_0020

Description

FIQ request register
Indication of the fast interrupt request detected with a positive edge

Bit No.

Name

Description

7 – 0

FIQIRR

Inputs 0 to 7 of the FIQ interrupt controller
'0' = No request
'1' = Request is occurred

FIQ_MASKREG

R/W

Addr.: 0x5000_0054

Default: 0x0000_00FF

Description

Interrupt mask register for FIQ
Enable/disable of FIQ interrupt inputs

Bit No.

Name

Description

7 – 0

FIQ_MASKREG

FIQ interrupt input 0 to 7
0' = Interrupt input enabled
'1' = Interrupt input disabled

IRREG

R

Addr.: 0x5000_0058

Default:0x0000_01xx

Description

Interrupt request register
Storage of interrupt requests that have occurred

Bit No.

Name

Description

15 – 0

IRREG

Interrupt input 0 to 15
0=Interrupt request inactive/1=Interrupt request active
Bit 5, 4, 3, 2 depending on GPIO 31, 30, 1, 0

MASKREG

R/W

Addr.: 0x5000_005C

Default: 0x0000_FFFF

Description

Interrupt mask register
Enable/disable of interrupt inputs

Bit No.

Name

Description

15 – 0

MASKREG

Interrupt input 0 to 15
0=Interrupt input enabled/1=Interrupt input disabled

ISREG

R

Addr.: 0x5000_0060

Default: 0x0000_0000

Description In-service

register

Indication of the interrupt requests confirmed by the CPU

Bit No.

Name

Description

15 – 0

ISREG

Interrupt input 0 to 15
0=Interrupt request not confirmed
1=Interrupt request has been confirmed

TRIGREG

R/W

Addr.: 0x5000_0064

Default: 0x0000_0000

Description

Trigger select register
Selection of interrupt detection

Bit No.

Name

Description

15 – 0

TRIGREG

Interrupt input 0 to 15
0=Interrupt detection via edge
1=Interrupt detection via level

EDGEREG

R/W

Addr.: 0x5000_0068

Default: 0x0000_0000

Description

Edge select register
Edge selection for interrupt detection
(only if edge detection is specified for the associated input)

Bit No.

Name

Description

15 – 0

EDGEREG

Interrupt input 0 to 15
0=Interrupt detection via positive edge
1=Interrupt detection via negative edge

Copyright © Siemens AG 2007. All rights reserved.

29

ERTEC 200 Manual

Technical data subject to change Version 1.1.0