No.

Signal Name

Alternative
Reset Function

I/O

(Reset)

Pull-

PIN

No.

Comment

EMIF (External Memory Interface)

109 WR_N

O (O)

A4

Write strobe

110 RD_N

O (O)

B5

Read strobe

111 CS_PER0_N

O (O)

D5

Chip Select Bank 1 (ROM);
boot area

112 CS_PER1_N

O (O)

A5

Chip select bank 2

113 CS_PER2_N

O (O)

A6

Chip select bank 3

114 CS_PER3_N

O (O)

B6

Chip select bank 4

115 BE0_DQM0_N

O (O)

N4

Byte enable 0 for D(7:0)

116 BE1_DQM1_N

O (O)

V1

Byte enable 1 for D(15:8)

117 BE2_DQM2_N

O (O)

J4

Byte enable 2 for D(23:16)

118 BE3_DQM3_N

O (O)

P5

Byte enable 3 for D(31:24)

119 RDY_PER_N

I (I)

up

D7

Ready signal

120 CLK_SDRAM

B (O)

M1

Clock for SDRAM

121 CS_SDRAM_N

O (O)

L1

Chip-Select for SDRAM

122 RAS_SDRAM_N

O (O)

M5

RAS for SDRAM

123 CAS_SDRAM_N

O (O)

L2

CAS for SDRAM

124 WE_SDRAM_N

O (O)

M4

Write Enable for SDRAM

1.5.7

LBU, MII Interface or ETM Trace Interface

No.

Function 1

LBU


Config

(6,5,2)=xx0b

Function 2

PHY Debug

and

GPIO[44:32]

Config

(6,5,2)=011b

Function 3

ETM Trace

and

GPIO[44:32]

Config

(6,5,2)=101b

Function 4


Reserved

[6,5,2]=111b

IO

(Reset

See

Config

[6,5,2])

Pull

-

PIN

No.

Comment

LBU / MII Interface/ ETM Trace Interface

125 LBU_A0

RXD_P10

ETMEXTOUT

I/O/O/I

(ETM : I)

up

AB3

LBU or MII or ETM

126 LBU_A1

RXD_P11

ETMEXTIN1

I/O/I/I

(ETM : I)

up

AA4

LBU or MII or ETM

127 LBU_A2

RXD_P12

TRACEPKT7

I/O/O/I

(ETM : I)

up

AA5

LBU or MII or ETM

128 LBU_A3

RXD_P13

TRACEPKT6

I/O/O/I

(ETM : I)

up

AB5

LBU or MII or ETM

129 LBU_A4

CRS_P1

TRACEPKT5

I/O/O/I

(ETM : I)

up

AA6

LBU or MII or ETM

130 LBU_A5

RX_ER_P1

TRACEPKT4

I/O/O/I

(ETM : I)

up

AB6

LBU or MII or ETM

131 LBU_A6

RX_DV_P1

TRACEPKT3

I/O/O/I

(ETM : I)

up

AA7

LBU or MII or ETM

132 LBU_A7

COL_P1

TRACEPKT2

I/O/O/I

(ETM : I)

up

AB7

LBU or MII or ETM

133 LBU_A8

RXD_P20

TRACEPKT1

I/O/O/I

(ETM : I)

up

AA8

LBU or MII or ETM

134 LBU_A9

RXD_P21

TRACEPKT0

I/O/O/I

(ETM : I)

up

AB8

LBU or MII or ETM

135 LBU_A10

RXD_P22

TRACESYNC

I/O/O/I

(ETM : I)

up

AA9

LBU or MII or ETM

136 LBU_A11

RXD_P23

PIPESTA2

I/O/O/I

(ETM : I)

up

AA10

LBU or MII or ETM

137 LBU_A12

CRS_P2

PIPESTA1

I/O/O/I

(ETM : I)

up

AB10

LBU or MII or ETM

138 LBU_A13

RX_ER_P2

PIPESTA0

I/O/O/I

(ETM : I)

up

AA11

LBU or MII or ETM

139 LBU_A14

RX_DV_P2

I/O/I/I

up

AB11

LBU or MII

140 LBU_A15

COL_P2

I/O/I/I

up

W11

LBU or MII