Lbu, mii interface or etm trace interface, No. function 1, Function 2 – Siemens ERTEC200 User Manual
Page 17: Function 3, Function 4
No.
Function 1
LBU
Config
(6,5,2)=xx0b
Function 2
PHY Debug
and
GPIO[44:32]
Config
(6,5,2)=011b
Function 3
ETM Trace
and
GPIO[44:32]
Config
(6,5,2)=101b
Function 4
Reserved
[6,5,2]=111b
IO
(Reset
See
Config
[6,5,2])
Pull
-
PIN
No.
Comment
LBU / MII-Interface
141 LBU_A16
GPIO32
GPIO32
I/B/B/B
(GPIO:I)
up
W9
LBU or GPIO
142 LBU_A17
GPIO33
GPIO33
I/B/B/B
(GPIO:I)
up
W10
LBU or GPIO
143 LBU_A18
GPIO34
GPIO34
I/B/B/B
(GPIO:I)
up
V10
LBU or GPIO
144 LBU_A19
GPIO35
GPIO35
I/B/B/B
(GPIO:I)
up
W12
LBU or GPIO
145 LBU_A20
GPIO36
GPIO36
I/B/B/B
(GPIO:I)
up
V12
LBU or GPIO
146 LBU_SEG_0
GPIO37
GPIO37
I/B/B/B
(GPIO:I)
up
V13
LBU or GPIO
147 LBU_SEG_1
GPIO38
GPIO38
I/B/B/B
(GPIO:I)
up
U13
LBU or GPIO
148 LBU_WR_N
TX_CLK_P1
I/O/I/I up
AA12
LBU or MII
LBU-Mode:
CONFIG[5] = 0 Write
Control (Low-Active)
CONFIG[5] = 1 RD/WR
Control (WR=0/RD=1)
149 LBU_RD_N
TX_CLK_P2
I/O/I/I up
AB13
LBU or MII
LBU-Mode:
CONFIG[5] = 0 Read
Control (Low Active)
CONFIG[5] = 1 -------
150 LBU_CS_R_
N
GPIO39
GPIO39
I/B/B/B
(GPIO : I)
up
AB12
LBU or GPIO
LBU-Mode:
CS for paging
configuration register
151 LBU_CS_M_
N
GPIO40
GPIO40
I/B/B/B
(GPIO : I)
up
U14
LBU or GPIO
LBU-Mode:
CS for ERTEC 200
resources
152 LBU_BE0_N
RX_CLK_P1
I/O/I/I
up
AB14
LBU or MII
153 LBU_BE1_N
RX_CLK_P2
I/O/I/I
up
AA13
LBU or MII
154 LBU_D0
TXD_P10
B/O/I/O
(LBU : I)
up
AA14
LBU or MII
155 LBU_D1
TXD_P11
B/O/I/O
(LBU : I)
up
W15
LBU or MII
156 LBU_D2
TXD_P12
B/O/I/O
(LBU : I)
up
AB16
LBU or MII
157 LBU_D3
TXD_P13
B/O/I/O
(LBU : I)
up
AA16
LBU or MII
158 LBU_D4
TX_EN_P1
B/O/I/O
(LBU : I)
up
AB17
LBU or MII
159 LBU_D5
TX_ERR_P1
B/O/I/O
(LBU : I)
up
AA17
LBU or MII
160 LBU_D6
TXD_P20
B/O/I/O
(LBU : I)
up
AB18
LBU or MII
161 LBU_D7
TXD_P21
B/O/I/O
(LBU : I)
up
AA18
LBU or MII
162 LBU_D8
TXD_P22
B/O/I/O
(LBU : I)
up
AB19
LBU or MII
163 LBU_D9
TXD_P23
B/O/I/O
(LBU : I)
up
AA19
LBU or MII
164 LBU_D10
TX_EN_P2
B/O/I/O
(LBU : I)
up
AA20
LBU or MII
165 LBU_D11
TX_ERR_P2
B/O/I/O
(LBU : I)
up
AB21
LBU or MII
Copyright © Siemens AG 2007. All rights reserved.
17
ERTEC 200 Manual
Technical data subject to change Version 1.1.0