Firmware upgrade procedure – Spectra Precision ProMark 800 Reference Manual User Manual
Page 129

117
Miscellaneous
receives them, then the rover position will automatically be 
delivered in the requested local coordinate system.
To output the position solution expressed in the projection 
received through RTCM message type 1025, enable the GMP 
NMEA message on the desired port.
Firmware Upgrade Procedure
Firmware upgrades can be downloaded from the Spectra 
Precision website in the form of one or more compressed 
“.tar.bz2” files. The file(s) provided, as well a the step-by 
step upgrade procedure are given in the relevant Release 
Note. 
Completing a firmware upgrade procedure may take up to 30 
minutes. For this reason, it must be run with the receiver 
powered from both a fully charged internal battery and the 
AC/DC power supply kit. You also need a USB key to make the 
upgrade files available to the receiver.
Follow the instructions below to complete the upgrade of your 
receiver:
1. Check that the USB key used for the upgrade is not write-
protected and then connect it to your computer.
2. Using Windows Explorer, copy the “.tar.bz2” file(s) to the
root directory of the USB key.
3. Check that there is at least 10 Mbytes of free memory left
on the USB key. The free memory will be used during the 
upgrade for decompressing data. 
4. Disconnect the USB key from the computer (after taking
the usual safety precautions related to the USB standard).
5. Make sure the receiver you want to upgrade is OFF and
ready for upgrade (i.e. internal battery present and 
external AC/DC power supply connected and on).