PLANET CS-1000 User Manual
Page 113
Multi-Homing Security Gateway User’s Manual
Step 16.
If you want to configure bi-direction VPN connection, you should enable Trunk setting in Outgoing
and Incoming Policy.
Outgoing Policy:
Incoming Policy:
Example 2. Create a VPN connection between the Multi-Homing Security Gateway and Windows XP
Professional VPN Client.
Preparation Task:
Company A External IP is 210.66.155.90, Internal IP is 192.168.10.X
Remote User External IP is 210.66.155.91
Remote user with an external IP wants to create a VPN connection with company A and connect to
192.168.10.100 for downloading the sharing file.
The Gateway of Company A is 192.168.10.1. The settings of company A are as the following.
Configuration of CS-1000
Step 1.
Enter the default IP of Company A’s Multi-Homing Security Gateway, 192.168.10.1. Click VPN in the
menu bar on the left hand side, and then select the sub-select IPSec Autokey. Click Add.
Step 2.
Enter the VPN name, VPN_A in IPSec Autokey window, and select the WAN interface you want to
create the VPN tunnel.
Step 3.
In to Destination table, choose Remote Gateway or Client – Dynamic IP.
- 107 -