B.16 defaults by drive model – Yaskawa Z1000U HVAC Matrix Bypass User Manual
Page 359

Table B.6 400 V Class Drives Default Settings by Drive Model Selection
No.
Name
Unit
Default Settings
–
Drive Model
–
4o0034
4o0040
4o0052
4o0065
o2-04
Drive Model Selection
Hex.
9C
9D
9E
9F
b3-04
V/f Gain during Speed Search
%
100
100
100
100
b3-06
Output Current 1 during Speed Search
–
0.5
0.5
0.5
0.5
b3-08
Current Control Gain during Speed Search
(Speed Estimation Type)
–
0.5
0.5
0.5
0.5
C6-02
Carrier Frequency Selection
–
1
1
1
1
E2-01
Motor Rated Current
A
26.5
32.9
38.6
52.3
E2-03
Motor No-Load Current
A
7.6
7.8
9.2
10.9
L2-02
Momentary Power Loss Ride-Thru Time
s
1
1
1
1.1
L2-03
Momentary Power Loss Minimum Baseblock
Time
s
0.6
0.6
0.6
0.6
L8-02
Overheat Alarm Level
°C
130
130
130
130
L8-38
Carrier Frequency Reduction Selection
–
1
1
1
1
Table B.7 400 V Class Drives Default Settings by Drive Model Selection
No.
Name
Unit
Default Settings
–
Drive Model
–
4o0077
4o0096
4o0124
4o0156
o2-04
Drive Model Selection
Hex.
A1
A2
A3
A4
b3-04
V/f Gain during Speed Search
%
100
100
80
60
b3-06
Output Current 1 during Speed Search
–
0.5
0.5
0.5
0.7
b3-08
Current Control Gain during Speed Search
(Speed Estimation Type)
–
0.5
0.5
0.5
0.8
C6-02
Carrier Frequency Selection
–
1
1
1
1
E2-01
Motor Rated Current
A
65.6
79.7
95
130
E2-03
Motor No-Load Current
A
19.1
22
24
36
L2-02
Momentary Power Loss Ride-Thru Time
s
1.1
1.2
1.2
1.3
L2-03
Momentary Power Loss Minimum Baseblock
Time
s
0.6
0.6
1
1
L8-02
Overheat Alarm Level
°C
130
130
130
130
L8-38
Carrier Frequency Reduction Selection
–
1
1
1
1
Table B.8 400 V Class Drives Default Settings by Drive Model Selection
No.
Name
Unit
Default Settings
–
Drive Model
–
4o0180
4o0216
4o0240
4o0302
4o0361
4o0414
o2-04
Drive Model Selection
Hex.
A5
A6
A7
A8
A9
AA
b3-04
V/f Gain during Speed Search
%
60
60
60
60
60
60
b3-06
Output Current 1 during Speed Search
–
0.7
0.7
0.7
0.7
0.7
0.7
b3-08
Current Control Gain during Speed
Search
(Speed Estimation Type)
–
0.8
0.8
0.8
0.8
0.8
0.8
C6-02
Carrier Frequency Selection
–
1
1
1
1
1
1
E2-01
Motor Rated Current
A
156
190
223
270
310
370
E2-03
Motor No-Load Current
A
40
49
58
70
81
96
L2-02
Momentary Power Loss Ride-Thru
Time
s
1.5
1.7
1.7
1.8
1.9
2
L2-03
Momentary Power Loss Minimum
Baseblock Time
s
1
1
1
1
1
1
L8-02
Overheat Alarm Level
°C
130
130
130
130
130
130
L8-38
Carrier Frequency Reduction
Selection
–
1
1
1
1
1
1
B.16 Defaults by Drive Model
YASKAWA SIEP YAIZ1D 01A Z1000U HVAC MATRIX Drive Bypass Technical Manual
359
B
Parameter List