Refer to, For a list of alarm codes, Minor faults and alarms – Yaskawa Z1000U HVAC Matrix Bypass User Manual
Page 233

HOA
Keypad
Display
Name
Page
ov
Control Circuit Overvoltage
SCF
Safety Circuit Fault
SEr
Too Many Speed Search Restarts
SoH
Snubber Discharge Resistor Overheat
SrC
Phase Order Detection Fault
Srr
Internal Resistance Fault
SvE
Zero Servo Fault
TdE
Time Data Error
TIM
Time Not Set
HOA
Keypad
Display
Name
Page
UL3
Undertorque Detection 1
UL5
Mechanical Weakening Detection 2
Uv1
<3>
Control Circuit Undervoltage Fault
Uv2
<3>
Control Power Supply Voltage Fault
Uv3
<3>
Undervoltage 3 (Soft-Charge Bypass Circuit
Fault)
<1> Displayed as CPF00 when occurring at drive power up. When one of the faults occurs after successfully starting the drive, the display will show
CPF01.
<2> Displayed as CPF20 when occurring at drive power up. When one of the faults occurs after successfully starting the drive, the display will show
CPF21.
<3> Fault histories are not kept when CPF00, CPF01, CPF06, CPF24, Fdv, oFA00, oFb00, oFC00, Uv1, Uv2, or Uv3 occur.
n
Minor Faults and Alarms
for an overview of possible alarm codes. Conditions such as overvoltages can trip faults and alarms. It is
important to distinguish between faults and alarms to determine the proper corrective actions.
When the drive detects an alarm, the ALM indicator LED blinks and the alarm code display flashes. Most alarms trigger a
digital output programmed for alarm output (H2-oo = 10). A fault (not an alarm) is present if the ALM LED lights without
for information on fault codes.
Table 6.5 Minor Fault and Alarm Displays
HOA
Keypad
Display
Name
Minor Fault
Output
(H2-oo = 10)
Page
AEr
Station Address Setting Error (CC-
Link, CANopen, MECHATROLINK)
YES
AL02
BAS Interlock Open
–
AL03
Smoke Purge in Bypass
–
AL04
Smoke Purge in Drive
–
AL13
Loss of Load
–
AL14
Serial Communications Alarm
–
AL16
Input Phase Rotation
–
AUv
Power Supply Undervoltage
YES
bb
Baseblock
No output
<2>
bUS
Option Card Communications Error
YES
CALL
Serial Communication Transmission
Error
YES
CE
MEMOBUS/Modbus Communication
Error
YES
CrST
Cannot Reset
YES
dnE
Drive Disabled
YES
doH
Damping Resistor Overheat
–
EF
Forward/Reverse Run Command
Input Error
YES
EF0
Option Card External Fault
YES
EF1 to
EF8
External Fault
(input terminal S1 to S8)
YES
FbH
Excessive PID Feedback
YES
FbL
PID Feedback Loss
YES
HOA
Keypad
Display
Name
Minor Fault
Output
(H2-oo = 10)
Page
Fdv
Power Supply Frequency Fault
–
HCA
Current Alarm
YES
inTLK
Interlock Open
–
LT-1
Cooling Fan Maintenance Time
No output
<1>
LT-2
Capacitor Maintenance Time
No output
<1>
LT-3
Soft Charge Bypass Relay
Maintenance Time
No output
<1>
oH
Heatsink Overheat
YES
oH2
Heatsink Overheat Warning
YES
oH3
Motor Overheat
YES
oL3
Overtorque 1
YES
ov
Control Circuit Overvoltage
YES
PASS
MEMOBUS/Modbus Test Mode
Complete
No output
SAFE
Customer Safety
–
SE
MEMOBUS/Modbus Test Mode Fault
YES
SoH
Snubber Discharge Resistor Overheat
YES
SrC
Phase Order Detection Fault
–
UL3
Undertorque Detection 1
YES
Uv1
Control Circuit Undervoltge
YES
WrUn
Waiting for Run
YES
<1> Output when H2-oo = 2F.
6.3 Drive Alarms, Faults, and Errors
YASKAWA SIEP YAIZ1D 01A Z1000U HVAC MATRIX Drive Bypass Technical Manual
233
6
Diagnostics & Troubleshooting