Devicenet option error codes – Yaskawa 1000 Series Drive Option - DeviceNet Technical Manual User Manual
Page 75
12 Troubleshooting
YASKAWA ELECTRIC
SIEP C730600 43B 1000-Series Option SI-N3 Technical Manual
75
Note: Refer to the MEMOBUS/Modbus Data Table in Appendix C of the drive Technical Manual for a list of monitor data using the
MEMOBUS/Modbus message area.
DeviceNet Option Error Codes
Table 21 DeviceNet Option Error Codes
15FF
Too much data
The data size is incorrect.
Correct the data size.
16FF
Object does not exist
An unsupported object was specified.
Correct the class or instance setting.
1FFF
Vendor specific error
Attempted to change a drive constant that
cannot be changed while the drive is running.
Attempted to change a drive constant to a
value outside of the setting range.
Stop the drive.
Specify a value that is within the setting range.
20FF
Invalid parameter
Attempted to change to a data value outside
of the setting range.
Specify a data value that is within the setting range.
Drive Error
Code
(hex)
DeviceNet
Error Code
(hex)
Description
Corrective Action
00
0000
None
-
01
5120
DC Bus Fuse Open (PUF)
Output Transistor Failure – Replace the drive
02
3220
DC Bus Undervolt (Uv1)
Input power fluctuation too large
03
5110
CTL PS Undervolt (Uv2)
Cycle drive power – Replace drive if fault continues
04
3222
MC Answerback (Uv3)
Cycle drive power – Replace drive if fault continues
05
2130
Short Circuit (SC)
Check drive wiring
Cycle drive power – Replace drive if fault continues.
06
2120
Ground Fault (GF)
Check for motor and/or cable damage
07
2300
Over Current (oC)
Check motor, motor load and acc/dec rates
08
3210
DC Bus Overvolt (ov)
Check incoming voltage
Check deceleration time
09
4200
Heatsink Overtemp (oH)
Check ambient temperature
Check drive cooling fan
0A
4210
Heatsink Max Temp (oH1)
Check drive cooling fan
0B
2220
Motor Overload (oL1)
Check the load, acc/dec and cycle times
Check motor rated current (E2-01)
0C
2200
Inv Overload (oL2)
Check the load, acc/dec and cycle times
Check drive rating
0D
2221
Overtorque Det 1 (oL3)
Check L6-02 and L6-03 settings
Check system mechanics
0E
2222
Overtorque Det 2 (oL4)
Check L6-05 and L6-06 settings
Check system mechanics
0F
7110
DynBrk Transistor (rr)
Cycle drive power – Replace drive if fault continues
10
7112
DynBrk Resistor (rH)
Check load, operating speed and deceleration time
11
9000
External Fault 3 (EF3)
Multifunction digital input set to external fault
Circuit at terminal is closed
12
9000
External Fault 4 (EF4)
13
9000
External Fault 5 (EF5)
14
9000
External Fault 6 (EF6)
15
9000
External Fault 7 (EF7)
16
9000
External Fault 8 (EF8)
17
4140
Heatsink Fan (FAn)
Check drive cooling fan
18
7310
Overspeed Det (oS)
Check reference and reference gain
Check F1-08 and F1-09 settings
19
7310
Speed Deviation (dEv)
Check load, acc/dec times and system mechanics
Check F1-10 and F1-11 settings
1A
7301
PG Open (PGo)
Check PG card connections
1B
3130
Input Phase Loss (PF)
Excessive input voltage fluctuation
1C
3130
Output Phase Loss (LF)
Check for broken wire/loose terminals
Check motor rating
1D
5210
None
-
1E
5300
Operator Disconnected (oPr)
Reconnect the digital operator
Error Code
Description
Cause
Possible Solution