beautypg.com

Yaskawa 1000 Series Drive Option - DeviceNet Technical Manual User Manual

Page 26

background image

8 Output Assemblies (Drive Consumes)

26

YASKAWA ELECTRIC SIEP C730600 43B 1000-Series Option SI-N3 Technical Manual

‹

Standard Control (Vendor Specific Yaskawa Electric (YE) Assy) - 101 (0x65)

Output

Instance

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

101

0

Multi-

Function Input

8

Multi-

Function Input

7

Multi-

Function Input

6

Multi-

Function Input

5

Multi-

Function Input

4

Multi-

Function Input

3

Run
Rev

Run

Fwd

1

Multi-

Function

Photocoupler 2

Multi-

Function

Photocoupler 1

Multi-

Function

Digital Output

Fault

Reset

External

Fault

2

Speed Reference (Low Byte)

3

Speed Reference (High Byte)

4

Torque Reference/Torque Limit (Low Byte)

5

Torque Reference/Torque Limit (High Byte)

6

Torque Compensation (Low Byte)

7

Torque Compensation (High Byte)

Output Instance

Byte

Run Fwd

Forward Run Command
0: Stop
1: Forward Run

Run Rev

Reverse Run Command
0: Stop
1: Reverse Run

Multi-Function Input 3

Terminal S3 Function Input
0: Terminal S3 Function (H1-03) OFF
1: Terminal S3 Function (H1-03) ON

Multi-Function Input 4

Terminal S4 Function Input
0: Terminal S4 Function (H1-04) OFF
1: Terminal S4 Function (H1-04) ON

Multi-Function Input 5

Terminal S5 Function Input
0: Terminal S5 Function (H1-05) OFF
1: Terminal S5 Function (H1-05) ON

Multi-Function Input 6

Terminal S6 Function Input
0: Terminal S6 Function (H1-06) OFF
1: Terminal S6 Function (H1-06) ON

Multi-Function Input 7

Terminal S7 Function Input
0: Terminal S7 Function (H1-07) OFF
1: Terminal S7 Function (H1-07) ON

Multi-Function Input 8

Terminal S8 Function Input
0: Terminal S8 Function (H1-08) OFF
1: Terminal S8 Function (H1-08) ON

External Fault

External Fault EF0
0: No External Fault (EF0)
1: External Fault (EF0)

Fault Reset

Fault Reset
0: No Fault Reset
1: Fault Reset

Multi-Function Digital Output

Terminal M1/M2
0: M1/M2 OFF
1: M1/M2 ON
This function is enabled only when H2-01 is set to F.

Multi-Function Photocoupler 1

Terminal P1
0: P1 OFF
1: P1 ON
This function is enabled only when H2-02 is set to F.

Multi-Function Photocoupler 2

Terminal P2
0: P2 OFF
1: P2 ON
This function is enabled only when H2-03 is set to F.