beautypg.com

Drive si-n3 – Yaskawa 1000 Series Drive Option - DeviceNet Technical Manual User Manual

Page 16

background image

5 Installation Procedure

16

YASKAWA ELECTRIC SIEP C730600 43B 1000-Series Option SI-N3 Technical Manual

Connection Diagram

Figure 10

Figure 10 Option Connection Diagram

<1> The ground wire provided in the option shipping package must be connected during installation.

7.

Route the option wiring.
Depending on the drive model, some drives may require routing wire through the side of the front cover to the
outside. In these cases, cut out the perforated openings in the left side of the drive front cover as shown in

Figure 11

-A, and leave no sharp edges to damage wiring.

Route the wiring inside the enclosure as show in

Figure 11

-B for drives that do not require routing through the

front cover. Refer to the Peripheral Devices & Options section of the drive Technical Manual for more
information.

Figure 11

Figure 11 Wire Routing Examples

8.

After wiring the terminal block, recheck the option wire routing performed in step

7.

A – Route wires through the

openings provided on the
left side of the front cover.

<1>

<1> The drive will not meet NEMA Type 1 requirements if wiring is exposed outside the

enclosure.

B – Use the open space

provided inside the drive
to route option wiring.

Drive

SI-N3

M

U
V

W

R

V+
V-
CAN_H
CAN_L

Shield

S

T

CN5-A

FE

<1>

DeviceNet Master

or

drop line

DeviceNet Cable

Motor

Power

(Red)

(Black)

(White)

(Blue)

B

A