beautypg.com

Setting the protection zone, 5 mac h ine set u p – HEIDENHAIN SW 548328-05 User Manual

Page 91

background image

HEIDENHAIN MANUALplus 620

91

3.5 Mac

h

ine set

u

p

Setting the protection zone

With active protection zone monitoring, the MANUALplus checks for
every movement whether the protection zone in –Z direction would
be damaged. If it detects such a violation, it stops the axis movement
and generates an error message.

The "Setting the protection zone" setup dialog shows the distance
between the machine zero point and the protection zone in –ZS.

The status of the protection zone monitoring is shown in the machine
display if it has been configured by the machine manufacturer (see
table).

Select Setting up

Select Set protection zone

Move the tool with the jog keys or handwheel until it reaches the
protection zone

Use the Take over position soft key to load this
position as protection zone

Enter the position of the protection zone relative to the workpiece zero
point (field: "Meas. pt. coordin.–Z")

Use the Save soft key to load the entered position as
protection zone

Switch off protective zone monitoring

Protection zone status

Protective zone monitoring active

Protective zone monitoring not active

SETTING THE PROTECTION ZONE/SWITCHING OFF THE MONITORING
FUNCTION

Protective zone monitoring is not active if the Set
protect zone

dialog box is open.

In DIN programming, you deactivate protective zone
monitoring with G60 Q1 and reactivate it with G60.

This manual is related to the following products: