Keystroke log file, Saving service files, 6 the er ro r messag es – HEIDENHAIN SW 548328-05 User Manual
Page 63
![background image](https://www.manualsdir.com/files/815756/content/doc063.png)
HEIDENHAIN MANUALplus 620
63
2.6 The er
ro
r messag
es
Keystroke log file
The MANUALplus stores keystrokes and important events (e.g.
system startup) in the keystroke log file. The capacity of the keystroke
log file is limited. If the log file is full, it switches to the next one, etc.
If the last log file is full, the first one is overwritten by a new one, etc.
If necessary, switch the log file to see the history. 10 log files are
available.
Open the keystroke log file.
Press the Log file soft key.
Open the log file.
Select previous log file, if needed.
Select current log file, if needed.
The MANUALplus saves each key pressed during operation in the
keystroke log file. The oldest entry is at the beginning of the log file,
and the most recent entry is at the end.
Saving service files
If necessary, you can save the "Current status of the MANUALplus,"
and make it available to a service technician for evaluation. A group of
service files is saved that contain information about the current status
of the machine and the machining. See "Service files" on page 555.
The information is summarized in a service files data record as a zip
file.
TNC:\SERVICEx.zip
The "x" designates a consecutive serial number. The MANUALplus
always generates the service file with the number 1, and all existing
files are renamed to the numbers 2 to 5. An existing file with the
number 5 is deleted.
Saving service files
Open the error window.
Press the Log file soft key.
Press the Service Files soft key.