beautypg.com

Transferring tool data, 3 t ransf er – HEIDENHAIN SW 548328-05 User Manual

Page 554

background image

554

Organization mode of operation

8.3 T

ransf

er

Transferring tool data

Tools are backed up in two steps:

Creating a tool backup: The parameters are archived in ZIP files
and stored in the control.

Transmitting/Receiving the tool backup files.

Restoring tools: Restores the backup files into the active data on
the MANUALplus (login required).

Tool selection

You can also create a tool backup without connecting to an external
storage device.

Press the Transfer soft key (login required).

Open the tool transfer.

Tool backup data

If you want to create a backup, you can define which tool data you
want to save in a selection window.

Selection for the content of backup files:

Tools

Tool texts

Technology data

Touch probes

Tool holders

Path and file names of the backup files:

\bck\tool\TO_*.zip

Press the Transmit or Receive soft key to start transferring the files.

When restoring backup data, all available content of the backup is
displayed in a selection window. Here you can select the tool data you
want to read in.

Soft keys for tool transfer

Transmits all marked files from the
control to the remote station.

Receives all files marked on the
remote station.

Deletes all marked files after a
confirmation prompt (login required).

Creates a tool backup data record as a
.zip file.

Restores data from the now selected
backup data record to the active
control system (login required).

Marks all files in the current window.

Marks or unmarks the file at the
cursor position and moves the cursor
down one position.

Selects the ZIP or HTT file type. The
tool data can also be transferred
directly as a HTT file (e.g. from a tool
presetter).

This manual is related to the following products: