Initial configuration process overview – Grass Valley Kameleon Series v.5.1.0 User Manual
Page 43

Kameleon Series Instruction Manual
43
Configuration and Adjustments
Status LED icon
The Status LED icon reports communication status for the frame slot and is
a link to the module Status page where Warnings and Faults are displayed.
LED colors indicate:
•
Green = Pass – no problems detected
•
Yellow = Configuration error warning
•
Red = Fault condition detected
Variables:
•
Model and Description are read-only generated by the module.
•
Frame Location is entered in 2000 Series Kameleon Frame configura-
tion.
•
Slot number reports the module’s location in the frame.
Initial Configuration Process Overview
To configure the Kameleon module proceed as follows:
1.
Go to the
I/O Config
page to setup and name inputs and outputs.
2.
If not already connected, connect all input and output signals. Go to the
module
Status
page to verify component and signal presence and
condition.
3.
Go to the
Video Input Select
page to configure the video source (not
required for KAM-SD) and output timing source.
4.
Go to
DEMUX
if you are demultiplexing audio from the video signal.
5.
Go to the
Functional Views
page to:
•
Verify the module’s functional configuration is correct, and
•
Begin with the Input block links to configure each function in turn.
Note
Next links are provided to help you navigate through a logical configuration
sequence.
6.
Use
E-MEM