Oxtel command forwarding to a co-processor – Grass Valley Imagestore 750 v.3.0.1 User Manual
Page 69

53
Imagestore 750
User Manual
Oxtel Command Forwarding to a Co-Processor
Serial Connection to Intuition XG
on page 207 for information on connecting the
Imagestore 750 and Intuition XG for command forwarding over a serial connection.
The keying layer parameter in the Oxtel automation protocol is always represented by a single
zero-based ASCII character in hexadecimal. The character can range from
0x0
to
0xF
. The
numbers for the four keying layers are reserved. The higher numbers are then used to address
layers on the associated graphics co-processor according to the following table:
For example, if an Imagestore 750 receives a command to load a graphic into layer
0x4
, it will
forward this command to the co-processor to load the graphic into the first keying layer. To do
this the Imagestore 750 subtracts 4 from the layer value before relaying the command.
Commands forwarded by the Imagestore 750 can potentially address up to 12 keying layers on
the co-processor. However, the usable range is 0x0 to 0xB because Intuition XG supports a
maximum of 8 keying layers.
Command forwarding is supported for the following Oxtel automation commands:
Layer Number
Co-Processor
Layer Number
Co-Processor
0x0 (DSK 1)
0x8
0x4
0x1 (DSK 2)
0x9
0x5
0x2 (DSK 3)
0xA
0x6
0x3 (DSK 4)
0xB
0x7
0x4
0x0
0xC
unused
0x5
0x1
0xD
unused
0x6
0x2
0xE
unused
0x7
0x3
0xF
unused
Table 4-15: Oxtel Command Keying layer forwarding to a Co-Processor
Cmd
Description
Cmd
Description
0
Fade To/From Black
Z2
Change Text Font and Color
1
Fade Keyer Up/Down
Z3
Render Box
2
Cut To/From Black
Z4
Change Image
3
Cut Keyer Up/Down
Z5
Run Strap
@
Set Fader Angle
Z6
Set Text Background to Matte
B
Set Transition Duration
Z7
Set Text Background to Gradient
8
Load Image From Library
Z8
Set Text Background to Clear
A
Erase Store
Z9
Set Text Drop Shadow
O
Enquire Loaded Image Status
ZA
Set Transparency
F
Set Clip Gain Transparency
ZB
Set Text Tracking
R0
Load Image
ZC
Set Strap Speed
R1
Save Image
ZD
Set Template Background
Table 4-16: Oxtel Commands supported by Command Forwarding