Grass Valley Imagestore 750 v.3.0.1 User Manual
Page 175

159
Imagestore 750
User Manual
individual system settings for the current configuration and modify them in the right-hand
pane. Whenever a setting is clicked, a description of the feature appears below it (in the right-
hand pane) as a helpful guide. The description includes the corresponding automation
command, which can be cross-referenced against the Oxtel series automation protocol docu-
ment. See the automation documents listed under
Applicable Publications and Tools
System settings are of two types:
Persistent
Settings from the
Setup
and
Config Alarms
front panel menus only.
State
Settings from the
Operate
front panel menu, which are volatile in nature.
Persistent System Settings
Persistent settings are options such as the serial port Baud rate (
Setup
>
Serial
Comms
>
Serial
Ports
>
COM
x
>
Baud
Rate
) which are always expected to persist after being modified during
commissioning. The Imagestore 750 Configurator allows such values to be defined within a
specific configuration
—
either to the factory default value or a custom-defined value.
State System Settings
State settings are options (from the ‘Operate’ menu) such as keyer fader positions and media
loads.
At restart, required state settings behavior might be:
•
Set to a specific value.
•
Set to their last system value.
State settings can be set to their last system value, by selecting ‘System value persists’ for the
parameter in the Imagestore 750 Configurator.
The possible restart behaviours of state settings are as follows:
•
Default value
Reset to the factory-default value.
•
User value
Reset to a user-defined value.
•
System value persists
Persist from the previous session.