beautypg.com

Displaying rmon statistics – H3C Technologies H3C WX5500E Series Access Controllers User Manual

Page 94

background image

84

4.

Configure an alarm entry, as described in

Table 28

.

5.

Click Apply.

Table 28 Configuration items

Item Description

Alarm variable:

Static Item

Set the traffic statistics that are collected and monitored. For more
information, see

Table 29

.

Interface Name

Set the name of the interface whose traffic statistics are collected
and monitored.

Sample Item:

Interval

Set the sampling interval.

Sample Type

Set the sampling type:

Absolute—Absolute sampling to obtain the value of the

variable when the sampling time is reached.

Delta—Delta sampling to obtain the variation value of the

variable during the sampling interval when the sampling time
is reached.

Owner:

Set the owner of the alarm entry.

Alarm:

Create Default Event

Select whether to create a default event.
The description of the default event is default event, the action is
log-and-trap, and the owner is default owner.
If there is no event, you can create the default event. And when the

value of the alarm variable is higher than the alarm rising
threshold or lower than the alarm falling threshold, the system

adopts the default action, that is, log-and-trap.

Rising Threshold

Set the alarm rising threshold.

Rising Event

Set the action that the system takes when the value of the alarm
variable is higher than the alarm rising threshold.
If you select the Create Default Event box, this option is not
configurable.

Falling Threshold

Set the alarm falling threshold.

Falling Event

Set the action that the system takes when the value of the alarm
variable is lower than the alarm falling threshold.
If you select the Create Default Event box, this option is not
configurable.

Displaying RMON statistics

1.

From the navigation tree, select Device > RMON.
The page in

Figure 69

appears.

2.

Click the

icon of the statistics entry of an interface.

The page for displaying RMON statistics appears.