Displaying rmon statistics – H3C Technologies H3C WX5500E Series Access Controllers User Manual
Page 94
84
4.
Configure an alarm entry, as described in
.
5.
Click Apply.
Table 28 Configuration items
Item Description
Alarm variable:
Static Item
Set the traffic statistics that are collected and monitored. For more
information, see
Interface Name
Set the name of the interface whose traffic statistics are collected
and monitored.
Sample Item:
Interval
Set the sampling interval.
Sample Type
Set the sampling type:
•
Absolute—Absolute sampling to obtain the value of the
variable when the sampling time is reached.
•
Delta—Delta sampling to obtain the variation value of the
variable during the sampling interval when the sampling time
is reached.
Owner:
Set the owner of the alarm entry.
Alarm:
Create Default Event
Select whether to create a default event.
The description of the default event is default event, the action is
log-and-trap, and the owner is default owner.
If there is no event, you can create the default event. And when the
value of the alarm variable is higher than the alarm rising
threshold or lower than the alarm falling threshold, the system
adopts the default action, that is, log-and-trap.
Rising Threshold
Set the alarm rising threshold.
Rising Event
Set the action that the system takes when the value of the alarm
variable is higher than the alarm rising threshold.
If you select the Create Default Event box, this option is not
configurable.
Falling Threshold
Set the alarm falling threshold.
Falling Event
Set the action that the system takes when the value of the alarm
variable is lower than the alarm falling threshold.
If you select the Create Default Event box, this option is not
configurable.
Displaying RMON statistics
1.
From the navigation tree, select Device > RMON.
The page in
appears.
2.
Click the
icon of the statistics entry of an interface.
The page for displaying RMON statistics appears.