6

Accessing the controller engine from the
switching engine

The controller engine and the switching engine of the WX5540E use independent operating systems,

Web interfaces, and CLI. From the perspective of SNMP, they are different entities. To access each

other's Web interfaces, they must have each other's IP address.
To enable automatic toggling between their Web interfaces, H3C already specified the default

management IP address of the switching engine on the controller engine, and specified the default IP

address of the controller engine on the switching engine.
If you are using the default settings, you do not need to perform the task described in "

Specifying

management IP addresses at the CLI

." If you have changed their management IP addresses, you must

perform the task.

Specifying management IP addresses at the CLI

Step Command

Remarks

1.

Enter system view of the
controller engine.

system-view

N/A

2.

Specify the management IP

address of the switching
engine.

oap management-ip ip-address
slot 0

By default, the management IP
address of the switching engine is

192.168.0.101.

3.

Return to user view.

quit

N/A

4.

Log in to the switching engine

from the controller engine.

oap connect slot 0

To return to the controller engine's
CLI, press Ctrl+K.

5.

Enter system view of the
switching engine.

system-view

N/A

6.

Specify the management IP
address of the controller

engine.

oap management-ip ip-address
slot 1

By default, the management IP
address of the controller engine is

192.168.0.100.

IMPORTANT:

After the configuration, make sure the switching engine and controller engine can reach each other.