background image

Switch Assembly, Lifter Sensing

1

Lift the printer clear of the HCI and place it on a smooth, sturdy surface.

2

Remove the top cover (2 screws).

3

Remove the back cover (4 screws, Figure 8-7, reference 5).

4

Disconnect the outside cables (connector with two cables) to release
Microswitch Assembly from the back top of the frame.

5

Remove the screw that holds the Microswitch mounting metallic bar to the
frame.

6

Take out the Microswitch Assembly (switch and metallic bar) by sliding the
bar towads the front of the assembly (Figure 8-7, reference 66).

7

Installation of the Microswitch Assembly is the reverse order.

Transfer Assembly

1

Open the Transfer Assembly and rotate the plastic cams (Figure 6-64,
callout 1) to the “open” position.

2

Unplug the connector (Figure 6-64, callout 2).

W A R N I N G !

Do not release the plastic cams while the Transfer Assembly is removed
from the chassis. The springs are very strong and may cause injury.

3

Remove (2) screws, CH110 (Figure 6-64, callout 3), and lift the assembly
straight up to clear the metal locating tabs.

To Reinstall:

W A R N I N G !

Release the plastic cams only after tightening the screws.

1

Make sure that the metal locating tabs are in place before tightening the
screws.

2

Release the plastic cams after tightening the screws.

6-78 Removal and Replacement