beautypg.com

Technical specifications, Table f.1, Echnical – RLE LD5200 V.2.3 User Manual

Page 117: Pecifications

background image

rletech.com

LD5200 User Guide

117

A

P P E N D I X

C

HAPTER

0

T

ECHNICAL

S

PECIFICATIONS

Table F.1 Technical Specifications

Power

100-240VAC @ 500mA Max, 50/60 Hz

Inputs

Sensing Cable

Compatible with all SeaHawk sensing cables (not included)

Cable Input

Requires SeaHawk LC-KIT: 15ft (4.57m) leader cable and

EOL (included)

Maximum Sensing Cable Length

10,000ft (3048m) of conductive fluid sensing cable or

7,000ft (2134m) of chemical resistant sensing cable

Minimum Sensing Cable Length

35ft (10.67m)

Detection Accuracy

± 2ft (0.6m)+/- 0.5% of the cable length

Detection Repeatability

± 2ft (0.6m) +/- 0.25% of the cable length

Detection Response Time

5-990sec., software adjustable in 5sec. increments; ±2sec.

Outputs

Analog

4-20mA Loop Powered, 18-36VDC, RL = 500ohm max.

Relay

1 DPDTLeak Relay, 1 DPDTCable Break Relay - each can

be sent to two places; 1A @ 24VDC, 0.5A resistive @

120VAC; configurable for supervised or non-supervised,

latched or non-latched

Maintenance Relay

1A @ 24VDC, 0.5A resistive @ 120VAC; configurable for

supervised or non-supervised, latched or non-latched

Communications Ports

EIA-485 (Port 1, Port 2, Port 3)

9600, 19200, or 38400 baud (selectable);
No parity, 8 data bits, 1 stop bit

EIA-232

9600 baud; No parity, 8 data bits, 1 stop bit

RJ-45

10/100BaseT Ethernet port (TCP/IP)

Protocols