Table F.1 Technical Specifications
Power
100-240VAC @ 500mA Max, 50/60 Hz
Inputs
Sensing Cable
Compatible with all SeaHawk sensing cables (not included)
Cable Input
Requires SeaHawk LC-KIT: 15ft (4.57m) leader cable and
EOL (included)
Maximum Sensing Cable Length
10,000ft (3048m) of conductive fluid sensing cable or
7,000ft (2134m) of chemical resistant sensing cable
Minimum Sensing Cable Length
35ft (10.67m)
Detection Accuracy
± 2ft (0.6m)+/- 0.5% of the cable length
Detection Repeatability
± 2ft (0.6m) +/- 0.25% of the cable length
Detection Response Time
5-990sec., software adjustable in 5sec. increments; ±2sec.
Outputs
Analog
4-20mA Loop Powered, 18-36VDC, RL = 500ohm max.
Relay
1 DPDTLeak Relay, 1 DPDTCable Break Relay - each can
be sent to two places; 1A @ 24VDC, 0.5A resistive @
120VAC; configurable for supervised or non-supervised,
latched or non-latched
Maintenance Relay
1A @ 24VDC, 0.5A resistive @ 120VAC; configurable for
supervised or non-supervised, latched or non-latched
Communications Ports
EIA-485 (Port 1, Port 2, Port 3)
9600, 19200, or 38400 baud (selectable);
No parity, 8 data bits, 1 stop bit
EIA-232
9600 baud; No parity, 8 data bits, 1 stop bit
RJ-45
10/100BaseT Ethernet port (TCP/IP)
Protocols