Chapter 2 Signal Conditioning VIs
ADAC LabVIEW VI
82
The Signal Conditioning VIs
The Signal Conditioning VIs are used convert analog input voltages
read from resistance temperature detectors (RTDs), or thermocouples
into units of temperature.
To access the ADAC Analog Output VIs, choose Functions
>> User
Libraries
>> ADAC >> Signal. Cond.
•
ADAC Thermo Linear (Convert Single Thermocouple Reading)
•
ADAC TC Lin Buff (Convert Thermocouple Buffer)
•
ADAC RTD Conv (Convert RTD Reading)
ADAC Thermo Linear (Convert Thermocouple Reading)
This VI Converts the specified thermocouple Source Voltage input array into the
specified temperature units.
Source Voltage Source Voltage is a single value containing the input data voltage to be
converted into temperature.
Thermocouple Type (0:BNBS) Thermocouple Type is a numeric value that specifies the
NBS thermocouple polynomial equation for the conversion. The available options are:
0:BNBS B-type thermocouple
1:KNBS K-type thermocouple
2:SNBS S-type thermocouple
3:TNBS T-type thermocouple
4:JNBS J-type thermocouple
5:RNBS R-type thermocouple
6:ENBS E-type thermocouple
The default Thermocouple Type is 0:BNBS