beautypg.com

Adac get board error – Measurement Computing ADAC-LVi User Manual

Page 111

background image

Chapter 2 Board Func Library

ADAC LabVIEW VI

105

ADAC Get Board Error

This VI returns the last hardware error code that occurred on the specified device. A
return error code of 0 indicates no hardware errors have occurred.

Device Handle (0) Device Handle is a numeric value that is used to identify the device
subsystem. The default Device Handle is 0.

error in (no error) Error in describes error conditions occurring before this VI executes.
This cluster defaults to no error.

Device Handle out Device Handle out contains the value of Device Handle in.

Error Number Error Number is a numeric value that represents the last board hardware
error code of the device. A return error code of 0 indicates no hardware errors have
occurred.

error out Error out contains error information. If the error in cluster indicated an error,
the error out cluster contains the same information. Otherwise, error out describes the
error status of this VI.