Chapter 2 Burst Config Library

ADAC LabVIEW VI

120

ADAC Set Burst Length

Burst Length is a numeric value that sets the number of samples obtained from a device
during a burst operation. This function is made available for hardware devices that
provide burst length mechanism. When the hardware device starts a burst, it provides (n)
more samples, then stops. The Burst samples specify the number of data samples to be
obtained after a valid hardware burst trigger.

Device Handle (0) Device Handle is a numeric value that is used to identify the device
subsystem. The default Device Handle is 0.

Burst Length (100) Burst Length is a numeric value that sets the number of samples
obtained by the device during a burst operation. This function is made available for
hardware devices that provide burst length mechanism. When the hardware device starts
a burst, it provides (n) more samples, then stops. The Burst samples specify the number
of data samples to be obtained after a valid hardware burst trigger.

The available Burst length is device independent and is verified by ADAC-LVi against
the min./max. burst length specified in the device's capabilities file.

error in (no error) Error in describes error conditions occurring before this VI executes.
This cluster defaults to no error.

Device Handle out Device Handle out contains the value of Device Handle in.

error out Error out contains error information. If the error in cluster indicated an error,
the error out cluster contains the same information. Otherwise, error out describes the
error status of this VI.