Measurement Computing ADAC-LVi User Manual
Page 42

Chapter 2 Utility Analog Input VIs
ADAC LabVIEW VI
36
$'$& $, :DYH 6FDQ FRQ¶W
Trigger Mode (0:disabled) Trigger Mode is a numeric value that sets the
hardware trigger operation mode. The available options are:
0:DISABLED All triggering is disabled.
1:ABOUT_TRIG Collect (N) data points before and (N) data points after a
trigger. Supported by A/D's ABOUT TRIGGER capabilities.
2:POST_TRIG Collect (N) data points after a trigger. supported by A/D's with
DMA, Interrupt or FIFO capabilities.
3:PRE_TRIG Collect (N) data points before a trigger. Supported by A/D's
ABOUT TRIGGER capabilities.
4:SCAN_TRIG Collect 1 data point for each channel after each trigger.
Supported by A/D's SCAN TRIGGER capabilities.
The default Trigger Mode is 0:DISABLED
Trigger Source (0:disabled) Trigger Source is a numeric value that sets the
hardware triggering source. The available options are:
0:DISABLED All triggering sources are disabled.
1:EXTERNAL Trigger the acquisition from an external event. Supported by
A/D's with DMA, Interrupt or FIFO capabilities.
2:CTR1 On-board counter 1 triggers the acquisition. Supported by A/D's with
DMA, Interrupt or FIFO capabilities.
3:CTR2 On-board counter 2 triggers the acquisition. Supported by A/D's with
DMA, Interrupt or FIFO capabilities.
The default Trigger Source is 0:DISABLED
Trigger Source Signal (0:falling) Trigger Source Signal is a numeric value that
sets the hardware triggering source signal. The available options are:
0:FALLING_EDGE Trigger on the falling edge of an event.
1:RISING_EDGE Trigger on the rising edge of an event.
The default Trigger Source Signal is 0:FALLING_EDGE