beautypg.com

Adac set software gate – Measurement Computing ADAC-LVi User Manual

Page 164

background image

Chapter 2 Gate Config Library

ADAC LabVIEW VI

158

ADAC Set Software Gate

This VI sets the hardware gate state of the device. The software gate can be either
enabled or disabled.

Device Handle (0) Device Handle is a numeric value that is used to identify the device
subsystem. The default Device Handle is 0.

Software Gate (DISABLED:0) Software Gate is a numeric value that sets the desired
hardware gate state of the device. The available options are:

0:DISABLED The device is stopped
1:ENABLED The device is enabled to run

The default SwGate state is 0:DISABLED

error in (no error) Error in describes error conditions occurring before this VI executes.
This cluster defaults to no error.

Device Handle out Device Handle out contains the value of Device Handle in.

error out Error out contains error information. If the error in cluster indicated an error,
the error out cluster contains the same information. Otherwise, error out describes the
error status of this VI.