SNM-1000 Node Control Modem

Revision 3

Operation

MN/SNM1000.IOM

3–55

3.7.5

Receive Control Channel Frequency (ICF)

This command sets the receive (NMS to remote) control channel IF frequency at the
remote node.

3.7.5.1 Command

Format

ICF 'cr'


Entered in MHz.
Range of 50 to 90 MHz, or 100 to 180 MHz
Resolution of 100 Hz.

Formatting is pseudo-floating point.

Example:

ICF 70.4567 sets receive control IF frequency to 70.4567 MHz.

3.7.5.2

Local Command Responses

ICF= , , offset>

3.7.6

Transmit Control Channel Frequency (OCF)

This command sets the transmit (remote to NMS) control channel IF frequency at the
remote node.

3.7.6.1 Command

Format

OCF 'cr'

Entered in MHz.
Range of 50 to 90 MHz, or 100 to 180 MHz.
Resolution of 100 Hz.

Formatting is pseudo-floating point.

Example:

OCF 70.1234 sets transmit control IF frequency to 70.1234 MHz.

3.7.6.2

Local Command Responses

OCF= , , offset>