Receive control channel frequency (icf), Transmit control channel frequency (ocf), 5 receive control channel frequency (icf) – Comtech EF Data SNM-1000 User Manual
Page 97: 1 command format, 2 local command responses, 6 transmit control channel frequency (ocf)
SNM-1000 Node Control Modem
Revision 3
Operation
MN/SNM1000.IOM
3–55
3.7.5
Receive Control Channel Frequency (ICF)
This command sets the receive (NMS to remote) control channel IF frequency at the
remote node.
3.7.5.1 Command
Format
ICF
Entered in MHz.
Range of 50 to 90 MHz, or 100 to 180 MHz
Resolution of 100 Hz.
Formatting is pseudo-floating point.
Example:
ICF 70.4567 sets receive control IF frequency to 70.4567 MHz.
3.7.5.2
Local Command Responses
ICF=
3.7.6
Transmit Control Channel Frequency (OCF)
This command sets the transmit (remote to NMS) control channel IF frequency at the
remote node.
3.7.6.1 Command
Format
OCF
Entered in MHz.
Range of 50 to 90 MHz, or 100 to 180 MHz.
Resolution of 100 Hz.
Formatting is pseudo-floating point.
Example:
OCF 70.1234 sets transmit control IF frequency to 70.1234 MHz.
3.7.6.2
Local Command Responses
OCF=