SNM-1000 Node Control Modem

Revision 3

Remote Control Operation

MN/SNM1000.IOM

A–8

Receive BPSK Data
Ordering

Command:
Response:

Status:
Response:

MC RDA_xxx'cr'
RDA_xxx'cr''lf']

MC RDA_'cr'
RDA_xxx'cr''lf']

Where: xxx = NRM (Standard) or INV (Non-
Standard).

Note: In RX Continuous mode only.

Bulk Demodulator
Configuration

Command:


Response:


BDC_BMNO,yyy.yyyy,ttttt,uuuuu,DDDD,
zzzz.zzz'cr'

BDC_BMNO,yyy.yyyy,ttttt,uuuuu,DDDD,
zzzz.zzz
'cr''lf']

Where:

B = Modulator set to Burst (B) or
Continuous (C).

M = Descrambler status OFF (0) or ON (1).

N = Differential Decoder status 0 or 1.

O = Reed Solomon Decoder status 0 or 1
(always 0).

yyy.yyyy = Input IF frequency 50.0 to
180.0 MHz.

ttttt = Sweep Center Frequency -35000 to
+35000.

uuuuu = Sweep Frequency Range 0 to
70000.

DDDD = Code Rate '1/2','3/4','7/8' ‘8/9’,
‘5/16’ (B516), ‘21/44’ (2144), or 'BP12'.

zzzz.zzz = Data Rate 4.800 to 2000.0 kbps
(limited by Code Rate).

Maximum Packet Size

Command:
Response:

BPS,xxxxxxxx'cr'
BPS,xxxxxxxx'cr''lf']

Where: xxxxxxxx = user length in bits, range of
2 to 16777216 bits (QPSK 1/2, Burst mode).

This command specifies the maximum user
data packet length that the SNM-1000 will
accept in Burst mode. If the received packet is
longer that the specified length, the modem
assumes that the packet has been corrupted
and enters the acquisition mode.