beautypg.com

6 interface:b-band loop back, B-band loop back off – Comtech EF Data SNM-1000 User Manual

Page 57

background image

SNM-1000 Node Control Modem

Revision 3

Operation

MN/SNM1000.IOM

3–15

3.4.1.3.6 INTERFACE:B-BAND

LOOP

BACK

B-BAND LOOP BACK

OFF

Programs the modem for baseband loopback operation, On or Off.

When baseband loopback is turned on, the data and timing signals are switched from the
demodulator to the modulator on the modem side of the interface. The DTE baseband
signals are also looped back from the transmitter data and clock to receiver data and clock
on the customer side of the interface. This is a bi-directional loopback of the baseband data.
Refer to figure 3-4 for a block diagram of baseband loopback operation.

Upon entry, the status is displayed. Press [

↑] or [↓] to make the selection. Press [ENTER]

to execute the change.

CUSTOMER

DATA

IBS OR IDR

INTERFACE

ENCODER/

MODULATOR

TRANSMIT RF

EQUIPMENT

ANTENNA

AC POWER

POWER SUPPLY

MICRO-

COMPUTER

REMOTE SERIAL

INTERFACE

FAULT INDICATORS

RECEIVE RF

EQUIPMENT

DEMODULATOR/

DECODER

SATELLITE MODEM

Figure 3-4. Baseband Loopback


Note: When baseband loopback is turned on, data is looped back on the customer side of the interface.
This is a bi-directional loopback of the baseband data. This test mode will verify the customer equipment
and cabling between the modem and the customer equipment. The baseband loopback is not bi-directional
in D&I.