Comtech EF Data SNM-1000 User Manual
Page 170

SNM-1000 Node Control Modem
Revision 3
Remote Control Operation
MN/SNM1000.IOM
A–22
Bulk 
Consolidated 
Status 
Command: 
Response: 
 
pn'cr''lf'] 
 
This command causes bulk modem status to be returned. 
 
To reduce the length of the response, message parameter 
data are returned without identifiers. However, parameter 
identification can be determined by order of return. Each 
status parameter (except for the last parameter) is terminated 
with a comma (','). The last parameter has the standard 
message termination sequence ('cr''lf']). 
 
Most of the data returned is formatted the same way as that 
returned by any single command status request (refer to 
Section A.3.2 for examples). 
 
Where: 'pn' is the last parameter returned. 
 
 
Parameter
Number
Parameter Name 
(Command Reference) 
 
Description 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
(Note 1) 
 
 
1
 
 
2
 
 
3
 
 
4
 
 
5
 
 
6
 
 
7
 
 
8
 
 
9
 
 
10
 
 
11
 
 
12
 
 
13
 
 
14
 
 
15
 
 
16
Modulator RF Output 
(ref. 'RF_' command). 
 
Modulator IF Frequency 
(ref. 'MF_' command). 
 
Modulator Rate 
(ref. 'MR_' command). 
 
Modulator Preset A assignment 
(ref. 'ARMA_' command). 
 
Modulator Preset B assignment 
(ref. 'ARMB_' command). 
 
Modulator Preset C assignment 
(ref. 'ARMC_' command). 
 
Modulator Preset D assignment 
(ref. 'ARMD_' command). 
 
Modulator Preset V assignment 
(ref. 'ARMV_' command). 
 
Modulator Power Offset 
(ref. 'MPO_' command). 
 
Modulator Output Power Level 
(ref. 'MOP_' command). 
 
Scrambler Enable 
(ref. 'SE_' command). 
 
Differential Encoder Enable 
(ref. 'DENC_' command). 
 
Modulator Type 
(ref. 'MT_' command). 
 
Modulator Encoder Type 
(ref. 'MET_' command). 
 
Transmit BPSK Data Ordering 
(ref. 'TDA_' command). 
 
Carrier Only Mode ON/OFF. 
 
p1 = n, where 'n' is '0' (OFF) or '1' (ON). 
 
 
p2 = nnn.nnnn, IF frequency in MHz. 
 
 
p3 = nnnn_mmm.mmm, code rate/data rate in kbps. 
 
 
p4 = nnnn_mmm.mmm, code rate/data rate in kbps. 
 
 
p5 = nnnn_mmm.mmm, code rate/data rate in kbps. 
 
 
p6 = nnnn_mmm.mmm, code rate/data rate in kbps. 
 
 
p7 = nnnn_mmm.mmm, code rate/data rate in kbps. 
 
 
p8 = nnnn_mmm.mmm, code rate/data rate in kbps. 
 
 
p9 = snn.n, modulator power offset in dB. 
 
 
p10 = snn.n, transmitter output power level in dBm. 
 
 
p11 = n, where 'n' is '0' (OFF) or '1' (ON). 
 
 
p12 = n, where 'n' is '0' (OFF) or '1' (ON). 
 
 
p13 = n, where 'n' is '0' (EFD), '1' (INTL), '2'(CSC), '3' (FDC), 
or '4' (SDM51). 
 
p14 = n, where 'n' is '0' (SEQ) or '1' (VIT). 
 
 
p15 = n, where 'n' is '0' (NRM), '1' (INV). 
 
 
p16 = n, where 'n' is '0' (OFF) or '1' (ON). 