beautypg.com

Comtech EF Data SNM-1000 User Manual

Page 170

background image

SNM-1000 Node Control Modem

Revision 3

Remote Control Operation

MN/SNM1000.IOM

A–22

Bulk
Consolidated
Status

Command:
Response:

MC BCS_'cr'
BCS_p1,p2,p3, . . .
pn'cr''lf']

This command causes bulk modem status to be returned.

To reduce the length of the response, message parameter
data are returned without identifiers. However, parameter
identification can be determined by order of return. Each
status parameter (except for the last parameter) is terminated
with a comma (','). The last parameter has the standard
message termination sequence ('cr''lf']).

Most of the data returned is formatted the same way as that
returned by any single command status request (refer to
Section A.3.2 for examples).

Where: 'pn' is the last parameter returned.

Parameter

Number

Parameter Name
(Command Reference)


Description











































(Note 1)

1


2


3


4


5


6


7


8


9


10


11


12


13


14


15


16

Modulator RF Output
(ref. 'RF_' command).

Modulator IF Frequency
(ref. 'MF_' command).

Modulator Rate
(ref. 'MR_' command).

Modulator Preset A assignment
(ref. 'ARMA_' command).

Modulator Preset B assignment
(ref. 'ARMB_' command).

Modulator Preset C assignment
(ref. 'ARMC_' command).

Modulator Preset D assignment
(ref. 'ARMD_' command).

Modulator Preset V assignment
(ref. 'ARMV_' command).

Modulator Power Offset
(ref. 'MPO_' command).

Modulator Output Power Level
(ref. 'MOP_' command).

Scrambler Enable
(ref. 'SE_' command).

Differential Encoder Enable
(ref. 'DENC_' command).

Modulator Type
(ref. 'MT_' command).

Modulator Encoder Type
(ref. 'MET_' command).

Transmit BPSK Data Ordering
(ref. 'TDA_' command).

Carrier Only Mode ON/OFF.

p1 = n, where 'n' is '0' (OFF) or '1' (ON).


p2 = nnn.nnnn, IF frequency in MHz.


p3 = nnnn_mmm.mmm, code rate/data rate in kbps.


p4 = nnnn_mmm.mmm, code rate/data rate in kbps.


p5 = nnnn_mmm.mmm, code rate/data rate in kbps.


p6 = nnnn_mmm.mmm, code rate/data rate in kbps.


p7 = nnnn_mmm.mmm, code rate/data rate in kbps.


p8 = nnnn_mmm.mmm, code rate/data rate in kbps.


p9 = snn.n, modulator power offset in dB.


p10 = snn.n, transmitter output power level in dBm.


p11 = n, where 'n' is '0' (OFF) or '1' (ON).


p12 = n, where 'n' is '0' (OFF) or '1' (ON).


p13 = n, where 'n' is '0' (EFD), '1' (INTL), '2'(CSC), '3' (FDC),
or '4' (SDM51).

p14 = n, where 'n' is '0' (SEQ) or '1' (VIT).


p15 = n, where 'n' is '0' (NRM), '1' (INV).


p16 = n, where 'n' is '0' (OFF) or '1' (ON).