Comtech EF Data SNM-1000 User Manual
Page 169

SNM-1000 Node Control Modem
Revision 3
Remote Control Operation
MN/SNM1000.IOM
A–21
Common
Equipment
Stored Faults
Command:
Response:
MM/DD/YY'cr'
M&C_xxx'cr'
INT_xxx'cr'
BAT_xxx'cr'
+5_xxx'cr'
+12_xxx'cr'
-12_xxx'cr''lf']
Monitor and Control Module (OK/FLT).
Data Interface Module (OK/FLT).
Battery/Clock (OK/FLT).
+5V Power Supply (OK/FLT).
+12V Power Supply (OK/FLT).
-12V Power Supply (OK/FLT).
Bulk
Consolidated
Analog
Status
Command:
Response:
BCAS_p1,p2,p3, . . . pn'cr''lf']
This command is similar to the 'BCS_' command, but returns
modem analog parameters.
Where: 'pn' is the last parameter returned.
Parameter
Number
Parameter Name
(Command Reference)
Description
(Note 1)
1
2
3
4
5
Receive Signal Level
(ref. 'RSL_' command).
Raw BER
(ref. 'RBER_' command).
Corrected BER
(ref. 'CBER_' command).
E
b
/N
0
(ref. ' EBN0 _' command).
Current Sweep Value
(ref. 'CSV_' command).
p1 = xsnn.n, receive signal level in dBm.
p2 = xm.mE-ee.
p3 = xm.mE-ee.
p4 = xnn.n, E
b
/N
0
in dB.
p5 = snnnnn, sweep offset value in Hz.
Notes:
1. Status only returned in Continuous mode.
2. Parameters 2 through 5 are dependent on carrier acquisition. If the decoder is not locked, empty data blocks are returned
(,,,,).