beautypg.com

Comtech EF Data SNM-1000 User Manual

Page 169

background image

SNM-1000 Node Control Modem

Revision 3

Remote Control Operation

MN/SNM1000.IOM

A–21

Common
Equipment
Stored Faults

Command:
Response:

MC CSF_#'cr'
CSF_# hh:mm:ss
MM/DD/YY'cr'
M&C_xxx'cr'
INT_xxx'cr'
BAT_xxx'cr'
+5_xxx'cr'
+12_xxx'cr'
-12_xxx'cr''lf']




Monitor and Control Module (OK/FLT).
Data Interface Module (OK/FLT).
Battery/Clock (OK/FLT).
+5V Power Supply (OK/FLT).
+12V Power Supply (OK/FLT).
-12V Power Supply (OK/FLT).

Bulk
Consolidated
Analog
Status

Command:
Response:

MC BCAS_'cr'

BCAS_p1,p2,p3, . . . pn'cr''lf']

This command is similar to the 'BCS_' command, but returns
modem analog parameters.

Where: 'pn' is the last parameter returned.

Parameter

Number

Parameter Name
(Command Reference)


Description










(Note 1)

1


2


3


4


5

Receive Signal Level
(ref. 'RSL_' command).

Raw BER
(ref. 'RBER_' command).

Corrected BER
(ref. 'CBER_' command).

E

b

/N

0

(ref. ' EBN0 _' command).

Current Sweep Value
(ref. 'CSV_' command).

p1 = xsnn.n, receive signal level in dBm.


p2 = xm.mE-ee.


p3 = xm.mE-ee.


p4 = xnn.n, E

b

/N

0

in dB.



p5 = snnnnn, sweep offset value in Hz.

Notes:

1. Status only returned in Continuous mode.

2. Parameters 2 through 5 are dependent on carrier acquisition. If the decoder is not locked, empty data blocks are returned
(,,,,).