Comtech EF Data SNM-1000 User Manual
Page 169

SNM-1000 Node Control Modem
Revision 3
Remote Control Operation
MN/SNM1000.IOM
A–21
Common 
Equipment 
Stored Faults 
Command: 
Response: 
 
 
MM/DD/YY'cr' 
M&C_xxx'cr' 
INT_xxx'cr' 
BAT_xxx'cr' 
+5_xxx'cr' 
+12_xxx'cr' 
-12_xxx'cr''lf'] 
 
 
 
Monitor and Control Module (OK/FLT). 
Data Interface Module (OK/FLT). 
Battery/Clock (OK/FLT). 
+5V Power Supply (OK/FLT). 
+12V Power Supply (OK/FLT). 
-12V Power Supply (OK/FLT). 
 
Bulk 
Consolidated 
Analog 
Status 
Command: 
Response: 
BCAS_p1,p2,p3, . . . pn'cr''lf'] 
 
This command is similar to the 'BCS_' command, but returns 
modem analog parameters. 
Where: 'pn' is the last parameter returned. 
 
 
Parameter
Number
Parameter Name 
(Command Reference) 
 
Description 
 
 
 
 
 
 
 
 
 
(Note 1) 
1
 
 
2
 
 
3
 
 
4
 
 
5
Receive Signal Level 
(ref. 'RSL_' command). 
 
Raw BER 
(ref. 'RBER_' command). 
 
Corrected BER 
(ref. 'CBER_' command). 
 
E
b
/N
0
(ref. ' EBN0 _' command). 
 
Current Sweep Value 
(ref. 'CSV_' command). 
p1 = xsnn.n, receive signal level in dBm. 
 
 
p2 = xm.mE-ee. 
 
 
p3 = xm.mE-ee. 
 
 
p4 = xnn.n, E
b
/N
0
in dB.
 
 
p5 = snnnnn, sweep offset value in Hz. 
Notes: 
 
1. Status only returned in Continuous mode.
2. Parameters 2 through 5 are dependent on carrier acquisition. If the decoder is not locked, empty data blocks are returned 
(,,,,). 
