Comtech EF Data SNM-1000 User Manual
Page 171

SNM-1000 Node Control Modem
Revision 3
Remote Control Operation
MN/SNM1000.IOM
A–23
Bulk
Consolidated Status
(continued
Where: 'pn' is the last parameter returned.
Parameter
Number
Parameter Name
(Command Reference)
Description
(Note 1)
(Note 1)
(Note 1)
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
Demodulator IF Frequency
(ref. 'DF_' command).
Demodulator Rate
(ref. 'DR_' command).
Demodulator Preset A Assignment
(ref. 'ADRA_' command).
Demodulator Preset B Assignment
(ref. 'ADRB_' command).
Demodulator Preset C Assignment
(ref. 'ADRC_' command).
Demodulator Preset D Assignment
(ref. 'ADRD_' command).
Demodulator Preset V Assignment
(ref. 'ADRV_' command).
Descrambler Enable
(ref. 'DE_' command).
Differential Decoder Enable
(ref. 'DDEC_' command).
RF Loopback
(ref. 'RFL_' command).
IF Loopback
(ref. 'IFL_' command).
Sweep Center Frequency
(ref. 'SCF_' command).
Sweep Width Range
(ref. 'SWR_' command).
BER Threshold
(ref. 'BERT_' command).
Demodulator Type
(ref. 'DT_' command).
Demodulator Decoder Type
(ref. 'DDT_' command).
Receive BPSK Data
(ref. 'RDA_' command).
Transmit Clock Source
(ref. 'TC_' command).
p17 = nnn.nnnn, demodulator IF frequency in MHz.
p18 = nnnn_mmm.mmm, code rate/data rate in kbps.
p19 = nnnn_mmm.mmm, code rate/data rate in kbps.
p20 = nnnn_mmm.mmm, code rate/data rate in kbps.
p21 = nnnn_mmm.mmm, code rate/data rate in kbps.
p22 = nnnn_mmm.mmm, code rate/data rate in kbps.
p23 = nnnn_mmm.mmm, code rate/data rate in kbps.
p24 = n, where 'n' is '0' (OFF) or '1' (ON).
p25 = n, where 'n' is '0' (OFF) or '1' (ON).
p26 = n, where 'n' is '0' (OFF) or '1' (ON).
p27 = n, where 'n' is '0' (OFF) or '1' (ON).
p28 = snnnnn, sweep center frequency in Hz.
p29 = nnnnn, sweep range in Hz.
p30 = xxxx, BER threshold.
p31 = n, where 'n' is '0' (EFD), '1' (INTL), '2' (CSC), or '3'
(FDC).
p32 = n, where 'n' is '0' (SEQ) or '1' (VIT).
p33 = n, where 'n' is '0' (NRM),or '1' (INV).