beautypg.com

Stored faults, A.8 stored faults – Comtech EF Data SNM-1000 User Manual

Page 168

background image

SNM-1000 Node Control Modem

Revision 3

Remote Control Operation

MN/SNM1000.IOM

A–20

A.8 Stored

Faults

Information on stored faults is returned when requested. If no stored fault exists for a given
fault number, the words ‘NO FAULT’ will be returned instead of the normal time/date and
status information.

The following symbols are used to define the stored faults status commands.

• #

Fault number (0 through 9), '0' is the first fault stored.

• hh

Hours in 24-hour format.

• mm Minutes.
• ss Seconds.
• MM Month.
• DD Day.
• YY Year.


Modulator
Stored Faults

Command:
Response:






Response:

MC MSF_#'cr'
MSF_# hh:mm:ss
MM/DD/YY'cr'
MOD_xxx'cr'
SYN_xxx'cr'
DCS_xxx'cr'
AGC_xxx'cr''lf']

MSF_# hh:mm:ss
MM/DD/YY'cr'
MOD_xxx'cr'
SYN_xxx'cr'
DCS_xxx'cr'
ICH_xxx'cr'
QCH_xxx'cr'
AGC_xxx'cr''lf']


TX Burst Mode:

Module (OK/FLT).
IF Synthesizer (OK/FLT).
Data Clock Synthesizer (OK/FLT).
AGC Level (OK/FLT).


TX Continuous Mode:

Module (OK/FLT).
IF Synthesizer (OK/FLT).
Data Clock Synthesizer (OK/FLT).
I Channel (OK/FLT).
Q Channel (OK/FLT).
AGC Level (OK/FLT).

Demodulator
Stored Faults

Command:

Response:

MC DSF_#'cr'

DSF_# hh:mm:ss
MM/DD/YY'cr'
MOD_xxx'cr'
CD_xxx'cr'
SYN_xxx'cr'
ICH_xxx'cr'
QCH_xxx'cr'
DSCR_xxx'cr'
BERT_xxx'cr''lf']




RX Continuous Mode:

Demod module (OK/FLT).
Carrier Detect (OK/FLT).
IF Synthesizer Lock (OK/FLT).
I Channel (OK/FLT).
Q Channel (OK/FLT).
Descrambler (OK/FLT).
BER Threshold (OK/FLT).