Comtech EF Data SNM-1000 User Manual
Page 164
SNM-1000 Node Control Modem
Revision 3
Remote Control Operation
MN/SNM1000.IOM
A–16
Interface Transmit
Side Status
Status:
Response:
Response:
CLK_xxx'cr'
SFLT_xx'cr''lf']
CLK_xxx'cr'
SFLT_xx'cr''lf']
TX Burst Mode:
Selected Transmit Clock Activity
(OK/FLT)
Number of Stored Faults Logged (0
through 10)
TX Continuous Mode:
Selected Transmit Clock Activity
(OK/FLT)
Number of Stored Faults Logged (0
through 10)
Interface Receive
Side Status
Status:
Response:
CLK_xxx'cr'
UNFL_xxx'cr'
OVFL_xxx'cr'
SFLT_xx'cr''lf']
Selected Buffer Clock Activity (OK/FLT)
Buffer Underflow (OK/FLT)
Buffer Overflow (OK/FLT)
Number of Stored Faults Logged (0 through
10)
Common Equipment
Status
Status:
Response:
M&C_xxx'cr'
INT_xxx'cr'
BAT_xxx'cr'
+5_xxx'cr'
+12_xxx'cr'
-12_xxx'cr'
MODE_xxxxxx'cr'
SFLT_xx'cr''lf']
M&C Module (OK/FLT)
Data Interface Module (OK/FLT)
Battery/Clock (OK/FLT)
+5V Power Supply (OK/FLT)
+12V Power Supply (OK/FLT)
-12V Power Supply (OK/FLT)
Mode (LOCAL or REMOTE)
Number of Stored Faults Logged (0 through
10)
The common equipment status command
causes the return of a block of data
indicating the common equipment status.