Comtech EF Data SNM-1000 User Manual
Page 164

SNM-1000 Node Control Modem
Revision 3
Remote Control Operation
MN/SNM1000.IOM
A–16
Interface Transmit 
Side Status 
Status: 
Response: 
 
 
 
 
 
Response: 
CLK_xxx'cr' 
SFLT_xx'cr''lf'] 
 
 
 
CLK_xxx'cr' 
 
SFLT_xx'cr''lf'] 
TX Burst Mode: 
 
Selected Transmit Clock Activity 
(OK/FLT) 
Number of Stored Faults Logged (0 
through 10) 
 
TX Continuous Mode: 
Selected Transmit Clock Activity 
(OK/FLT) 
Number of Stored Faults Logged (0 
through 10) 
 
Interface Receive 
Side Status 
Status: 
Response: 
 
 
 
 
CLK_xxx'cr' 
UNFL_xxx'cr' 
OVFL_xxx'cr' 
SFLT_xx'cr''lf'] 
 
 
Selected Buffer Clock Activity (OK/FLT) 
Buffer Underflow (OK/FLT) 
Buffer Overflow (OK/FLT) 
Number of Stored Faults Logged (0 through 
10) 
 
Common Equipment 
Status 
Status: 
Response: 
 
 
 
 
M&C_xxx'cr' 
INT_xxx'cr' 
BAT_xxx'cr' 
+5_xxx'cr' 
+12_xxx'cr' 
-12_xxx'cr' 
MODE_xxxxxx'cr' 
SFLT_xx'cr''lf'] 
 
 
M&C Module (OK/FLT) 
Data Interface Module (OK/FLT) 
Battery/Clock (OK/FLT) 
+5V Power Supply (OK/FLT) 
+12V Power Supply (OK/FLT) 
-12V Power Supply (OK/FLT) 
Mode (LOCAL or REMOTE) 
Number of Stored Faults Logged (0 through 
10) 
 
The common equipment status command 
causes the return of a block of data 
indicating the common equipment status. 
 
