Maintenance
MN/SNM1000.IOM
5–12
5.1.3.2.1 Demodulator
Checkout
Use the following procedure to test the demodulator.
1. Set up the equipment. Refer to Chapter 4 for the demodulator specifications. 
 
2. Set up the modem with an external IF loop and level. Use a properly operating 
modulator, and ensure that power levels, data rates, code rates, etc., are 
compatible. 
 
3. Allow the modem to lock up. Depending on the data rate and overhead type, 
lock up may take several seconds. When the green carrier detect LED is on and 
the DEMUX lock fault has been cleared (where applicable), the modem will run 
at the specified error rate. Run the TX power level (input amplitude) over the full 
range, and offset the TX frequency from the RX frequency by 35 kHz. Ensure the 
modem still runs within the specified error rate. 
 
4. Set up the modem to check the constellation patterns with an oscilloscope that is 
set in the X-Y mode. Typical constellation patterns with noise and without noise. 
These test points are available on the auxiliary connector (J9, pins 6 and 8). It is 
not necessary to open the modem to look at these test points. 