Comtech EF Data SNM-1000 User Manual
Page 167

SNM-1000 Node Control Modem
Revision 3
Remote Control Operation
MN/SNM1000.IOM
A–19
Receive Signal Level
Status
Status:
Response:
Where:
x = < or > (data modifier to indicate that
the receive signal level is less than or
greater than the returned value).
s = + or - (receive signal level sign).
nn.n = 0.0 to 99.9 (receive signal level
magnitude).
Notes:
1. The 'x' (< or >) parameter is only
returned if the level has exceeded
the computational resolution of the
system.
2. 'No Data' is returned if the level
cannot be calculated.
3. 'Sampling' is returned if not enough
data is currently available to
calculate the level.
Current Sweep Value
Status:
Response:
Where:
x = < or > (data modifier to indicate that
the sweep offset value is less than or
greater than the returned value).
s = + or - (sweep offset from center).
nnnnn = 0 to 35000.
This command returns the current sweep
offset value.
Notes:
1. The 'x' (< or >) parameter is only
returned if the level has exceeded
the computational resolution of the
system.
2. 'No Data' is returned if the level
cannot be calculated.
3. 'Sampling' is returned if not enough
data is currently available to
calculate the level.
4. In RX Continuous mode only.