background image

SNM-1000 Node Control Modem

Revision 3

Operation

MN/SNM1000.IOM

3–18

3.4.2 FUNCTION

SELECT:MONITOR

FUNCTION SELECT

MONITOR

3.4.2.1 MONITOR:RAW

BER

RAW BER
NO DATA


Displays the current BER or “No Data” (if carrier is not locked).

Range: < m.m E-e to > m.m E-e.

Note: Low limit is based on performance. High limit is based on data/code rate.

3.4.2.2 MONITOR:CORRECTED

BER

CORRECTED BER

NO DATA


Displays the current corrected BER or “No Data” (if carrier is not locked).

Range: 1.0 E-3 to 1.0 E-12.

Note: Low limit is based on performance. High limit is 1.0 E-12.