Comtech EF Data SNM-1000 User Manual

Page 54

background image

SNM-1000 Node Control Modem

Revision 3

Operation

MN/SNM1000.IOM

3–12

3.4.1.2.10 DEMODULATOR:REACQUISITION

REACQUISITION

0 SECONDS


Displays the sweep reacquisition mode time duration. This is the time that the modem
will remain in a narrow sweep after loss of acquisition. After this timer runs out, the
modem will return to the normal acquisition sweep. The reacquisition time is 0 to 999
seconds. Default: 0 seconds.

3.4.1.3 CONFIGURATION:INTERFACE

CONFIGURATION

INTERFACE

3.4.1.3.1

INTERFACE:TX CLOCK SOURCE

TX CLOCK SOURCE

SCT (INTERNAL)


Programs the clock source for the modem transmitter clock to the following
configurations:

TX Terrestrial

Sets the TX clock to recover timing from the incoming clock/data.

SCT (INTERNAL)

Sets the TX clock to operate from the modem internal clock (this also is the
fallback clock).

Note: When loop timing is enabled, SCT (LOOP) is displayed instead of
SCT (INTERNAL).

EXT CLOCK

Sets the TX clock to operate from the EXT-CLK clock. Transmit clock source
must be phase/frequency locked to the data that is being transmitted. The
correct frequency must be programmed into EXT-CLK FREQ.


Upon entry, the current TX clock source is displayed. Press [

↑ ] or [↓ ] to make the

selection. Press to execute the change.