2.3.2

Fault Connector and Pinouts (J7)

The fault connector provides Form C contact closures for fault reporting. The three Form C
summary fault contacts, ratings 1A maximum at 24 VDC, 0.5A at 120 VAC, are
Modulator, Demodulator, and Common Equipment.

The fault interface connection is a 9-pin subminiature female D connector (J7) located on
the rear panel of the modem. Screw locks are provided for mechanical security on the
mating connector. Refer to Table 2-2 for pinout information.

Table 2-2. Fault Connector and Pinouts (J7)

Pin #

Signal Function

Name

1

Common equipment is not faulted

NO

2

COM

3

Common equipment is faulted

NC

4

Modulator is not faulted

NO

5

COM

6

Modulator is faulted

NC

7

Demodulator is not faulted

NO

8

COM

9

Demodulator is faulted

NC

Note: A connection between the common (COM) and normally open (NO)
contacts indicates no fault.


Refer to Chapter 5 for a discussion of monitored faults. To obtain a system summary
fault, connect all the Form C contacts in parallel.