Figure 1 – Zilog Z86193 User Manual
Page 9
Z8
®
CPU
User Manual
UM001604-0108
Z8
®
CPU Product Overview
2
default WDT clock source is an internal RC circuit (isolated from the device clock
source).
Auto Reset/Low-Voltage Protection—
All family devices have internal Power-On Reset.
ROM devices add low-voltage protection. Low-voltage protection ensures the MCU is in
a known state at all times (in active RUN or RESET modes) without external hardware (or
a device reset pin).
Low-EMI Operation—
Mode is programmable via software or as a mask option. This new
option provides for reduced radiated emission via clock and output drive circuit changes.
Low-Power—
CMOS with two standby modes; STOP and HALT.
Full Z8
®
Instruction Set—
Forty-eight basic instructions, supported by six addressing
modes with the ability to operate on bits, nibbles, bytes, and words.
Figure 1. Z8 CPU Block Diagram
Port 3
Counter/
Timers (2)
Interrupt
Control
Analog
Comparators
(2)
Output
Input
ALU
FLAG
Register
Pointer
Register File
256 x 8-Bit
Machine Timing
& Instruction Control
RESET, WDT,
POR
Prg. Memory
512/K x 8-Bit
Program
Counter
V
CC
GND
XTAL
Address or I/O
(
Nibble Programmable)
Port 2
Port 0
Port 1
AS DS R/W RESET
4
4
8
Address/Data or I/O
(
Byte Programmable
)
I/O
(
Bit Programmable)
- Z86233 Z86243 Z86733 Z86743 Z86C02 Z86C04 Z86C08 Z86C15 Z86C21 Z86C30 Z86C31 Z86C33 Z86C36 Z86C40 Z86C43 Z86C61 Z86C62 Z86C63 Z86C65 Z86C83 Z86C90 Z86C91 Z86C93 Z86C96 Z86E02 Z86E03 Z86E04 Z86E06 Z86E07 Z86E08 Z86E15 Z86E21 Z86E30 Z86E31 Z86E33 Z86E34 Z86E40 Z86E43 Z86E44 Z86E61 Z86E63 Z86E83 Z86K15 Z86L02 Z86L04 Z86L08 Z86L16 Z8E000 Z8E001 Z8PE003