Load external data – Zilog Z86193 User Manual
Page 206
Z8
®
CPU
User Manual
UM001604-0108
Instruction Description
199
Load External Data
Syntax
LDE dst, src
Instruction Format
Operation
dst
←
src
This instruction is used to load a byte from external data memory into a Working Register
or vice versa. The address of the external data memory location is specified by a Working
Register Pair. The contents of the source operand are not affected.
Example 1
If Working Register Pair R6 and R7 contain the value
40A2h
and external data memory
location
40A2h
contains the value
22h
, the statement:
LDE R2, @RR6
Op Code: 82 26
loads the value
22h
into Working Register R2. The value of external data memory loca-
tion
40A2h
is unchanged by the load.
Example 2
If Working Register Pair R6 and R7 contain the value
404Ah
and Working Register R2
contains the value
22h
, the statement:
LDE @RR6, R2
Op Code: 92 26
Cycles
OPC
(Hex)
Address Mode
dst
src
OPC
dst src
12
82
r
Irr
OPC
src dst
12
92
Irr
r
Flag
Description
C
Unaffected
Z
Unaffected
S
Unaffected
V
Unaffected
D
Unaffected
H
Unaffected
- Z86233 Z86243 Z86733 Z86743 Z86C02 Z86C04 Z86C08 Z86C15 Z86C21 Z86C30 Z86C31 Z86C33 Z86C36 Z86C40 Z86C43 Z86C61 Z86C62 Z86C63 Z86C65 Z86C83 Z86C90 Z86C91 Z86C93 Z86C96 Z86E02 Z86E03 Z86E04 Z86E06 Z86E07 Z86E08 Z86E15 Z86E21 Z86E30 Z86E31 Z86E33 Z86E34 Z86E40 Z86E43 Z86E44 Z86E61 Z86E63 Z86E83 Z86K15 Z86L02 Z86L04 Z86L08 Z86L16 Z8E000 Z8E001 Z8PE003