Halt – Zilog Z86193 User Manual
Page 189
Z8
®
CPU
User Manual
UM001604-0108
Instruction Description
182
Halt
Syntax
HALT
Instruction Format
Operation
The HALT instruction turns off the internal CPU clock, but not the XTAL oscillation. The
counter/timers and the external interrupts IRQ1, IRQ2, and IRQ3 remain active. The
devices are recovered by interrupts, either externally or internally generated.
In order to enter HALT mode, it is necessary to first flush the instruction pipeline to avoid
suspending execution in mid-instruction. You must execute a NOP immediately before the
execution of the HALT instruction.
Example
Assuming the Z8
®
CPU is in normal operation, the statements:
NOP
HALT
Op Codes: FF 7F
place the Z8 CPU into HALT mode.
Cycles
OPC
(Hex)
OPC
6
7F
Flag
Description
C
Unaffected
Z
Unaffected
S
Unaffected
V
Unaffected
D
Unaffected
H
Unaffected
Note:
- Z86233 Z86243 Z86733 Z86743 Z86C02 Z86C04 Z86C08 Z86C15 Z86C21 Z86C30 Z86C31 Z86C33 Z86C36 Z86C40 Z86C43 Z86C61 Z86C62 Z86C63 Z86C65 Z86C83 Z86C90 Z86C91 Z86C93 Z86C96 Z86E02 Z86E03 Z86E04 Z86E06 Z86E07 Z86E08 Z86E15 Z86E21 Z86E30 Z86E31 Z86E33 Z86E34 Z86E40 Z86E43 Z86E44 Z86E61 Z86E63 Z86E83 Z86K15 Z86L02 Z86L04 Z86L08 Z86L16 Z8E000 Z8E001 Z8PE003