Status elements, Status elements –17 – Altera Stratix IV GX FPGA Development Board User Manual
Page 25

Chapter 2: Board Components
2–17
Configuration, Status, and Setup Elements
August 2012
Altera Corporation
Stratix IV GX FPGA Development Board
Reference Manual
Status Elements
The development board includes status LEDs. This section describes the status
elements.
lists the LED board references, names, and functional descriptions.
lists the board-specific LEDs component references and manufacturing
information.
Table 2–9. Board-Specific LEDs
Board Reference
LED Name
Description
D24
POWER
Blue LED. Illuminates when 3.3-V power is active.
D5
CONF DONE
Green LED. Illuminates when the FPGA is successfully configured. Driven by the
MAX II CPLD EPM2210 System Controller.
D26
Loading
Green LED. Illuminates when the MAX II CPLD EPM2210 System Controller is
actively configuring the FPGA. Driven by the MAX II CPLD EPM2210 System
Controller wire-OR'd with the Embedded Blaster CPLD.
D27
Error
Red LED. Illuminates when the MAX II CPLD EPM2210 System Controller fails to
configure the FPGA. Driven by the MAX II CPLD EPM2210 System Controller.
D35
ENET TX
Green LED. Blinks to indicate Ethernet PHY transmit activity. Driven by the Marvell
88E1111 PHY.
D34
ENET RX
Green LED. Blinks to indicate Ethernet PHY receive activity. Driven by the Marvell
88E1111 PHY.
D33
100
Green LED. Illuminates to indicate Ethernet linked at 100 Mbps connection speed
Driven by the Marvell 88E1111 PHY.
D32
1000
Green LED. Illuminates to indicate Ethernet linked at 1000 Mbps connection speed.
Driven by the Marvell 88E1111 PHY.
D1
HSMC Port A
Present
Green LED. Illuminates when the HSMC port A has a board or cable plugged-in
such that pin 160 becomes grounded. Driven by the add-in card.
D2
HSMC Port B
Present
Green LED. Illuminates when the HSMC port B has a board or cable plugged-in
such that pin 160 becomes grounded. Driven by the add-in card.
D30
MUTE
Green LED. Illuminates when the SDI receiver carrier detect is active.
D40
FAN LED
Green LED. Illuminates when a heat sink or fan should be installed. Driven by the
MAX1619 thermal sensor OVERTEMPn signal.
Table 2–10. Board-Specific LEDs Component References and Manufacturing Information
Board Reference
Description
Manufacturer
Manufacturer
Part Number
Manufacturer
Website
D1, D2, D26
Green LEDs
Lumex Inc.
SML-LX1206GC-TR
D27
Red LED
Lumex Inc.
SML-LX1206USBC-TR
D24
Blue LED
Lumex Inc.
SML-LX1206USBC-TR