Lingenfelter L250280197 Lingenfelter C5 Corvette E-Force Supercharger Install Kit v2.9 User Manual
Page 81
Page 80
282. Using a 10mm socket, re-install the lower
air deflector by tightening both bolts. If the old air
deflector is worn out or damaged, it may cause
the engine to overheat. Inspect the air deflector
and replace if necessary.
283. Re-install the rear hood seal back on to
the cowl lip.
284. Fill the power steering fluid reservoir. Take
care not to get dirt inside of the power steering
reservoir.
285. Fill the engine coolant reservoir with
orange Dex-Cool antifreeze in the proper mixture
ratio.
NOTE: LPE recommends using two (2) different
color coolants. One color for the intercooler
system, and the other color coolant for your
engine cooling. This is to differentiate between
the intercooler and the cooling system if a leak
occurs. OEM Corvette coolant for the engine is
orange so use green for the supercharger.