61. Reinstall the knock sensors.
These are torqued to 15 ft-lbs.
CAUTION: Take care not to drop, damage, or
over-torque the knock sensors.
60. This illustration shows which hole on each
side needs to be plugged by the coolant bleed
plugs. Be sure to plug the non-threaded holes.
62. Remove the clips, as well as the tape from
knock sensor harness. Remove the loom from
the rear sensor wire.
63. Use tape to hold the knock sensor
harness into the machined groove in the
valley tray. Route the connector under the
A.I.R. tube and connect to the engine harness.
CAUTION: Take care not to pinch or damage the
knock sensor harness wires.