beautypg.com

Chapter 9 - droplet size monitor, Droplet size monitor setup, Pressure sensor – TeeJet Matrix Pro 840GS User Manual

Page 77: Low pressure alarm (psi), Droplet size monitor setup pressure sensor

background image

71

98-05273-ENUS R4

HOME

OVER

VIE

W

SE

TUP

IMPLEMENT

FULL SCREEN

GPS

INTR

ODUC

TION

GUID

ANCE

DR

OPLE

T MONIT

OR

CHAPTER 9 - dROPLET sizE MONiTOR

Droplet Size Monitor Setup is used to configure and enable the Droplet Size Monitor (DSM). A Pressure Sensor Interface Kit is required to

enable the Droplet Size Monitor. The DSM is available on all guidance pages via the status bar.

drOPlet SiZe MOnitOr SetUP

Pressure sensor

When a Pressure Sensor Interface Kit is present, Pressure Sensor

options are used to enter the sensor manufacture's maximum

pressure rating and set high and low user determined pressure

alarms.
NOTE: If a Pressure Sensor Interface Kit is being used, the Droplet

Size Monitor will be available.

1. Press CONFIGURATION side tab

.

2. Press

Sensors

.

3. Press

Pressure Sensor

.

4. Press the KEYPAD icon

to select from:

►Maximum Pressure Rating – used to establish the maximum

pressure rating of the pressure sensor as recommended by the

manufacturer

►Low Pressure Alarm– used to enter the user determined low

pressure point at which the alarm will sound

►High Pressure Alarm– used to enter the user determined high

pressure point at which the alarm will sound

5. Use the numeric keypad to enter a value.
6. Press the ACCEPT icon

to save the settings or the CANCEL

icon

to leave the keypad without saving.

7. Press RETURN arrow or CONFIGURATION side tab

to

return to the main Configuration screen.

Figure 9-1: Pressure Sensor

low Pressure alarm (psi)

1

2

3

0.0

Clear

4

5

6

<--

7

8

9

0

.

+/-